Installation Instructions - InfraStyle / InfraStyle i
Installation
EN
Installation
This chapter describes how to install the relay box and the control panel.
NOTICE
Damage due to incorrect mounting location
The control panel is not suitable for outdoor use.
It must be operated only inside buildings and may not be ex-
posed to environmental conditions such as extreme humidity
and moisture or the possible formation of condensation or cor-
rosive substances in the ambient air, as well as other weather
conditions.
Similarly, excessive cold and extreme exposure to sunlight must
be prevented.
Protect the unit accordingly if there is an increased risk of me-
chanical damage.
4.1 Power supply and data lines
All electrical installations and all connecting lines routed inside the cabin
must be suitable for an ambient temperature of at least 70°C in infrared-
only cabins.
All lines must be routed in such a way that they are well-protected, e.g. in a
cable conduit.
NOTICE
Electronics malfunctions
Routing data and power supply lines together can lead to elec-
tronics malfunctions because, e.g. because the sensor will not be
detected.
Do not route sensor and sauna bus lines together with power
supply lines.
Route separate cable conduits.