26
Installation Instructions - InfraStyle / InfraStyle i
Installation
EN
4.2.3 Installing cabin lighting
Lighting can be installed anywhere, however not near rising hot air or in
the direct emitting range of an IR emitter. The light output is set to induc-
tive load by default, but light bulbs, halogen HV bulbs and other resistive
loads may also be connected to it. If required, the light output can also be
manually set to capacitive loads.
Setting the light output, see 6.6 Defining the light source manually,
Cabin lighting is not included in the scope of delivery. Observe the sepa-
rate installation instructions for lighting.
Light source requirements:
Lighting must be dimmable
Minimal output 5 W
Resistive loads max. 100 W
Dimmable energy-saving bulbs max. 35 W
Light sources with conventional transformers max. 60 VA
Dimmable LED bulbs max. 60 W
NOTICE
Material damage
Lighting and the control panel could become damaged if non-
dimmable light sources are installed. In this case, the warranty be-
comes void.
Do not install lighting in the emitting range of an IR emitter.
The lighting must conform to protection class IPX4 (splash-
proof) and be resistant to ambient temperatures.
Connect only dimmable light sources.
Control line connection: