InfraStyle / InfraStyle i - Installation Instructions
35
Installation
Line routing for InfraStyle i
Guide for data and control line(s)
The control line must only be routed between the insulation and the outer
wall of the cabin. Cabin insulation must be installed in such a way that the
temperature in the area in which cables are routed cannot exceed 75°C.
The InfraStyle i voltage regulator may not be exposed to elevated tempera-
tures. It may not be mounted in the cabin wall.
The voltage regulator must be mounted within a 3-m radius of the control
panel. It may also be placed on the roof of the cabin.
Extending the control panel's control line
For longer connections, special RJ10/RJ14 connecting cables with lengths
of 10 m, 25 m, 50 m and 100 m are available as an option.
Alternately, the supplied (as standard) 5-m line can also be extended with
an RJ12/RJ12 coupling and an RJ12/RJ12 extension cord.
The extensions and couplings are available as options.
See Accessories (optional),
A
Inner wall of the cabin
B
Insulation
C
Control line
D
Outer wall of the cabin
E
Voltage regulator (InfraStyle i only)
A
B
D
C
E