TUTORIALS
Controlling an Air over Oil System
198 |
P a g e
Copyright © 2021 BF ENTRON and/or its affiliates. All rights reserved
Product Model:
iPAK2v2
Firmware Version:
V2.10
May 22 | Doc No 700253-2
5
Program
Squeeze
time with a value
sufficient to allow the cylinder to build to the
Intensify pressure or Weld Force
6
Program remaining weld parameters to suit
weld schedule.
Review step 3 to confirm the AV2 column is
checked for each event of the weld program
in use (
Squeeze, Upslope, Main
heat, Downslope, Hold
).
Table 74: Instructions to program a Weld Program for an Air-Over-Oil System
Figure 76: Example Weld Program for Air-Over Oil System using AV2 for Intensify Output