12)
Check the Status Screen for the
Restart Required
message. restart the control by cycling the
power to the control or clicking Restart Control button.
13)
If the Restart Required message is present, restart the control by cycling the power to the control or
clicking Restart Control button.
14)
Navigate to the
Calibrate Current
tab
15)
Set the
Factor
signal based on the expected Secondary Current
a.
If the current is not expected to exceed 50 kA, then set the factor to
1
b.
If the current is expected to exceed 50 kA, then the factor should be set based on the TAM/1
and the attenuator option (x1, x2, x3, etc.)
16)
Navigate to the
Program
tab
a.
If the active weld program has an
Electrode Stepper
programmed, the stepper must be reset to
ensure the stepper does not modify the output during calibration.
i.
Navigate to the
Electrode Tab
ii.
Check the
Enable Stepper
checkbox
iii.
Click the Reset stepper/electrode checkbox
iv.
Verify
0
in the
Spots done
textbox
v.
Disable the Electrode stepper for the calibration procedure by unchecking the
Enable
Stepper
checkbox