COMMUNICATIONS SETUP
WSP3 Pendant
71 |
P a g e
Copyright © 2021 BF ENTRON and/or its affiliates. All rights reserved
Product Model:
iPAK2v2
Firmware Version:
V2.10
May 22 | Doc No 700253-2
3.5
WSP3 Pendant
The WSP3 is a handheld pendant that can be purchased with a control. The device can be used for reading status
information, programming parameters, and store a backup of the control settings. The WSP3 is a flexible device
designed to work with the entire iPAK and EN7000 product families. In other words, one WSP3 Pendant can be used to
program multiple ENTRON
controls in a user’s facility.
The iPAK2v2 does not need to be configured to communicate with a WSP3 Pendant.
The steps for connecting the WSP3 Pendant to the iPAK2v2 are as follows:
1)
Connect the WSP3 Pendant to the iPAK2v2 weld control via a RS232 cable
2)
Turn ON the iPAK2v2 weld control
3)
The WSP3 Pendant will power up with the weld control. After diagnostics have been run and the control
has initialized, the WSP3 will show
READY
.
Figure 21: WSP3 Screen Example
WELD OFF
When the Weld Input signal is open, the pendant will flash
WELD OFF
. This
means that the iPAK2V2 control will not pass weld current when the START
input is initiated.
FAULTS PRESENT
If faults are present such as a missing Thermostat and Estop signal, the fault
messages will be displayed on the fist line of the pendant. The messages will
displayed in a rotating manner. One message is displayed at a time.
Ready
▌
-- 0 A
prog 0
-
▌
- 11.7 kA
5.66 kN
--
▌
0 A
~30.5%