INTRODUCTION
Installation
53 |
P a g e
Copyright © 2021 BF ENTRON and/or its affiliates. All rights reserved
Product Model:
iPAK2v2
Firmware Version:
V2.10
May 22 | Doc No 700253-2
6)
For the active weld program
a.
Set the
Squeeze
time to
1999
ms
b.
Set the
Upslope
to
0
c.
set the
Main Heat Mode
to
CCu
d.
set the
Main Heat
value to a low value such as
10.0%
e.
set the
Main heat
time to
200
ms.
7)
Produce a short circuit weld
8)
Note the following values:
H1 = % Heat target from the
Program
tab
Is1 = weld current from the Log tab in NetFlash™ or current displayed on the WSP3 pendant.
9)
For the active weld program, set the
Heat
value to a higher value such as
80
%
10)
Produce a short circuit weld
11)
Note the following values:
H2 = % Heat target from the
Program
tab
Is2 = weld current from the Log tab in NetFlash™ or current displayed on the WSP3 pendant.
Current Output
The previous calibration procedure has calibrated the output current of the iPAK2v2
to the machine. Therefore
, the output current of the iPAK2v2 should be used
in the
CCC procedure.
12)
Navigate to the
Calibrate CCC
tab