TUTORIALS
Configuring & Calibrating iPAK2v2 with the WSP3 Pendant
214 |
P a g e
Copyright © 2021 BF ENTRON and/or its affiliates. All rights reserved
Product Model:
iPAK2v2
Firmware Version:
V2.10
May 22 | Doc No 700253-2
Step
Description
Screen / Parameters
Key Inputs
9
Scroll up to the
EDIT
PROGRAM
line and press
the
RETURN
key
10
On the
PROGRAM
line use
the + and
–
keys to select
PROGRAM 0
Note
–
the program selected here
will be used for the short circuit
welds to calibrate the control.
11
Scroll down to
EDIT TIME
and press the
RETURN
key
12
Program the weld times
with the following settings
Parameter
Value
SQUEEZE
1999 ms
UPSLOPE
0 ms
MAIN HEAT
200 ms
DOWNSLOPE 0 ms
HOLD
500 ms
13
Press F to return to the
PROGRAM
MENU
14
Scroll to the
EDIT
CURRENT
line and press
the
RETURN
key
15
Program the weld currents
with the following settings
Parameter
Value
MAIN: MODE
CCu
MAIN: HEAT
40.0%
MAIN: CURRENT
8.00 KA
MAIN: MONITOR NO
LOW LIMIT
5%
HIGH LIMIT
5%
16
Press F to return to the
PROGRAM
menu
17
Scroll down to the
EDIT
OPTIONS
menu and press
the
RETURN
key
<<<MAIN MENU>>>
EDIT PROGRAM
<<<PROGRAM 0>>>
Use +/- keys to alter a
selected parameter
<<<PROGRAM 0>>>
EDIT TIME
Use +/- keys to alter a
selected parameter
<<<PROGRAM 0>>>
EDIT TIME
EDIT CURRENT
Use +/- keys to alter a
selected parameter
<<<PROGRAM 0>>>
EDIT TIME