ADVANCED FEATURES
Multi-weld Operations
182 |
P a g e
Copyright © 2021 BF ENTRON and/or its affiliates. All rights reserved
Product Model:
iPAK2v2
Firmware Version:
V2.10
May 22 | Doc No 700253-2
9.7.3.1
Multi-Electrode in Extended Mode
For Multi-Electrode operation in Extended mode, the
Electrodes
configuration parameter must be set to
Multi
as shown
in
Figure 57: Location of Electrodes Configuration Parameter in NetFlash
Using One or More Weld Air Valves
Extended
mode is required when using one or more Weld Air Valves on a Multi-
Electrode (Multi-Gun) machine.
Extended
configuration allows a user to output the WAV signal on any of the discrete outputs ranging from AV1 to AV8.
In
NetFlash™,
check the
AVx
and
WAVx
box corresponding to the desired valve and timing parameter to execute during
the weld sequence. The selected
WAVx
output will
automatically stay ON
throughout the entire weld sequence.
When the
WAVx
checkbox is checked, the
AVx
outputs in the column shown in
The
AVx
output will execute for all events.