ENFORCER
Heavy-Duty Outdoor Access Control Keypad with Proximity Reader
SECO-LARM U.S.A., Inc.
9
Wiring Diagram:
Connection Terminals
Terminal
Description
12~24 VAC/VDC
Connect to a 12~24 VAC/VDC
power supply.
Observe polarity.
Output 1 N.C.
NO/NC/COM relay output,
Max. 5A@24VDC
Output 1 COM
Output 1 N.O.
Output 2 N.C.
NO/NC/COM relay output,
Max. 1A@24VDC
Output 2 COM
Output 2 N.O.
Egress Input
N.O. Pushbutton contact to
ground. Press button to activate
Output #1
Output 3 N.C.
NO/NC/COM relay output,
Max. 1A@24VDC
Output 3 COM
Output 3 N.O.
K or A output
Transistor ground output, max.
100mA@24VDC. See "K or A"
jumper information below for
programming details.
Duress output
Transistor ground output, max. 100mA@24VDC. Switches to ground (–) to trigger
a silent alarm or other device when a user enters a duress code.
Ground (–)
Common ground output.
Door Sensor
Connect to an optional N.C. sensor such as a magnetic contact to monitor if a
door is open or closed. Connect to ground (–) if not used.
Output 1 inhibit
Output #1 inhibitor. N.O. input, connect to Interlock Control of second keypad if
needed so that if one keypad is used to open a door, the other is temporarily
disabled.
Interlock Control
Interlock control. N.O. input, connect to Output 1 Inhibit of second keypad if
needed so that if one keypad is used to open a door, the other is temporarily
disabled.
Tamper N.C.
Tamper switch output, N.C. contact, max. 50mA@24VDC. Connect to the N.C.
24-hour protection zone of an alarm if needed.
Jumper Settings
Jumper
Position Description
Backlit
Full
Dim backlit during standby. Full backlit for 10 seconds after any button press.
Auto
No backlit during standby. Full backlit for 10 seconds after any button press.
K or A
K
Switches to ground (–) for 10 seconds after any button press.
A
Switches to ground (–) when alarm occurs to trigger optional auxiliary alarm.
BACK-LIT
Jumper Positions
Backlit – Full
Backlit – Auto
K or A – Keypress
K or A – Alarm
FULL AUTO
BACK-LIT
FULL AUTO
K OR A
KEY ALARM
K OR A
KEY ALARM