ENFORCER
Heavy-Duty Outdoor Access Control Keypad with Proximity Reader
SECO-LARM U.S.A., Inc.
3
Quick Programming Guide:
This page is for installers looking to do a basic installation and programming of the keypad. For
more in-depth installation and programming instructions, see the Table of Contents, pg. 4.
Programming Tips:
•
The master programming, super user, common user, visitor, duress, and user codes
cannot be the same.
•
A flashing amber LED indicates the keypad is in standby mode. A solid amber LED indicates the
keypad is in programming mode.
•
If the keypad is set for
Auto Entry Mode, your codes
will need to be
the same number of
digits as the master programming code
(see pgs. 28~29).
Programming Instructions:
Follow the instructions below if the following covers your needs:
•
A new master programming code.
•
A single 4-digit user code for all users, and no proximity cards.
•
One output to unlock a door.
•
A 3-second delay time in opening the door after the output is activated.
1.
Turn off the beeping before the 1-minute power-up period ends:
2.
Enter Programming Mode:
NOTE:
is the default master programming code.
3.
Change the master programming code:
NOTE:
is the new master programming code.
4.
Set the user code to operate output #1 (unlock the door):
NOTE:
chooses user ID #000 of 1,000 possible users (000~999).
is the new user code for user ID #000.
5.
Set the output #1 delay time (skip this step if the default value of 5 seconds is
acceptable):
NOTE:
sets the output #1 delay time for 3 seconds.
6.
Exit Programming Mode: