background image

EMX Industries, Inc.                                                Tech support: 216-518-9889 

1/9

 

Document No.10579100 Rev 2.5                              [email protected]

 

 

 

KPX-100

 

  Programmable Keypad 

 

Instruction Manual 

 

The  KPX-100  is  a  dual  relay  output,  programmable  keypad.  It  features  a  durable  metal  housing  
and  metal  backlit  keys  designed  for  high  traffic  areas  and  harsh  environments.  
Connect this  keypad to door  strike controls, security systems  or automatic gate and door operators.  
The KPX-100 easily mounts on gooseneck stands, posts or walls.  

 

  

 

 

Power 

12-24 VDC/AC  

Standby Current 

16 mA 

Detection Current 

78 mA 

Environmental Rating 

IP66 

Operating Temperature 

-4º to 158ºF (-20º to 70ºC) 5 to 95% relative humidity  

Housing Material 

Powder coated steel with stainless steel faceplate 

Dimensions (L x W x H) 

6.14” (156 mm) x 4.1” (103 mm) x 2.76” (50 mm) 

Specifications 

Status 

Tones 

Left LED 

Orange LED 

Right LED 

Programming Mode 

--- 

--- 

Flashes 

--- 

Successful Key Entry Relay 1 

Determined by 

code 81 

--- 

1 flash 

Solid green 

LED 

Successful Key Entry Relay 2 

Determined by 

code 81 

Solid red LED 

1 flash 

--- 

Unsuccessful Key Entry 

5 beeps 

--- 

3 flashes 

--- 

Successful Code Entry 

2 beeps 

--- 

2 flashes 

--- 

Unsuccessful Code Entry 

5 beeps 

--- 

5 flashes 

--- 

DAP Jumper Not Replaced 

Continuous 

beeps 

--- 

Flashes continuously 

--- 

Standby Mode 

--- 

--- 

1 flash every  

2 seconds 

--- 

Lock-Up Mode 

5 beeps 

On 

1 flash every  

2 seconds 

Solid red LED 

Indicators 

TM 

Summary of Contents for KPX-100

Page 1: ...nmental Rating IP66 Operating Temperature 4º to 158ºF 20º to 70ºC 5 to 95 relative humidity Housing Material Powder coated steel with stainless steel faceplate Dimensions L x W x H 6 14 156 mm x 4 1 103 mm x 2 76 50 mm Specifications Status Tones Left LED Orange LED Right LED Programming Mode Flashes Successful Key Entry Relay 1 Determined by code 81 1 flash Solid green LED Successful Key Entry Re...

Page 2: ...o ground after a duress key has been entered It is often used to trigger an alarm an auto dialer or a buzzer 12 Common Ground 13 Door Position Sensor Input N C normally close input terminal See door sensor wiring diagram to the right Always connect terminal 13 to ground if not in use 14 Output 1 Inhibit N O normally open input terminal Both relay 1 user keys and egress button cannot activate outpu...

Page 3: ... two KPX 100 with cross wire connections on the output 1 inhibit 14 and inter lock control output 15 terminals Connect the common ground terminals 12 of the two keypads Use N O relay output for fail secure locking and N C output for fail safe locking An inter lock system prevents both doors from being open at the same time for a more secure entry Keypad Back Lighting jumper selected 1 Backlit The ...

Page 4: ...8 digits of your choice followed by 0 5 To change the programming key press 0 and then 4 digits of your choice followed by 0 6 To create user keys for relay 1 and 2 press the relay number the user number and then 4 8 digits of your choice followed by Relay 1 can have 100 user keys relay 2 can have 10 user keys User keys must be the same length as the programming key if planning on using auto entry...

Page 5: ...ase user codes and programming code Must add programming code back after change 8 9 0 0 Sets the mode and clears all previously stored data and modes Single user mode assigns one user key per relay Multi User Mode Reset Only use to change modes will erase user codes and programming code Must add programming code back after change 8 9 0 1 Sets the mode and clears all previously stored data and mode...

Page 6: ...n the door is forced open Output through terminal 13 Correct Key Entry Tones 8 1 0 8 1 1 8 1 2 Keypad does not beep upon correct key entry Keypad beeps twice upon correct key entry Keypad beeps once upon correct key entry default User Key Entry Mode 8 2 0 8 2 1 Requires after user key is entered default Keypad does not require after user key is entered All user keys must match Programming key leng...

Page 7: ... 5 seconds the keypad will beep before output 1 activates Press and hold the egress button for 10 seconds the keypad will beep before output 1 activates Troubleshooting Symptom Possible Cause Solution Forgotten programming key Forgotten programming key 1 Disconnect the power supply 2 Move the DAP jumper from OFF to ON 3 Reconnect the power supply The keypad will start beeping 4 Move the DAP jumper...

Page 8: ...tion Record Loc Code Loc Code 00 50 01 51 02 52 03 53 04 54 05 55 06 56 07 57 08 58 09 59 10 60 11 61 12 62 13 63 14 64 15 65 16 66 17 67 18 68 19 69 20 70 21 71 22 72 23 73 24 74 25 75 26 76 27 77 28 89 29 79 30 80 31 81 32 82 33 83 34 84 35 85 36 86 37 87 38 88 39 89 40 90 41 91 42 92 43 93 44 94 45 95 46 96 47 97 48 98 49 99 ...

Page 9: ... support 216 518 9889 9 9 Document No 10579100 Rev 2 5 technical emxinc com EMX Industries Inc products have a warranty against defects in materials and workmanship for a period of two years from date of sale to our customer ...

Reviews: