background image

EMX Industries, Inc.                                                Tech support: 216-518-9889 

8/9

 

Document No.10579100 Rev 2.5                              [email protected]

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Warranty 

 

User Codes and Location Record 

Loc 

Code 

 

Loc 

Code 

00 

 

 

50 

 

01 

 

 

51 

 

02 

 

 

52 

 

03 

 

 

53 

 

04 

 

 

54 

 

05 

 

 

55 

 

06 

 

 

56 

 

07 

 

 

57 

 

08 

 

 

58 

 

09 

 

 

59 

 

10 

 

 

60 

 

11 

 

 

61 

 

12 

 

 

62 

 

13 

 

 

63 

 

14 

 

 

64 

 

15 

 

 

65 

 

16 

 

 

66 

 

17 

 

 

67 

 

18 

 

 

68 

 

19 

 

 

69 

 

20 

 

 

70 

 

21 

 

 

71 

 

22 

 

 

72 

 

23 

 

 

73 

 

24 

 

 

74 

 

25 

 

 

75 

 

26 

 

 

76 

 

27 

 

 

77 

 

28 

 

 

89 

 

29 

 

 

79 

 

30 

 

 

80 

 

31 

 

 

81 

 

32 

 

 

82 

 

33 

 

 

83 

 

34 

 

 

84 

 

35 

 

 

85 

 

36 

 

 

86 

 

37 

 

 

87 

 

38 

 

 

88 

 

39 

 

 

89 

 

40 

 

 

90 

 

41 

 

 

91 

 

42 

 

 

92 

 

43 

 

 

93 

 

44 

 

 

94 

 

45 

 

 

95 

 

46 

 

 

96 

 

47 

 

 

97 

 

48 

 

 

98 

 

49 

 

 

99 

 

Summary of Contents for KPX-100

Page 1: ...nmental Rating IP66 Operating Temperature 4º to 158ºF 20º to 70ºC 5 to 95 relative humidity Housing Material Powder coated steel with stainless steel faceplate Dimensions L x W x H 6 14 156 mm x 4 1 103 mm x 2 76 50 mm Specifications Status Tones Left LED Orange LED Right LED Programming Mode Flashes Successful Key Entry Relay 1 Determined by code 81 1 flash Solid green LED Successful Key Entry Re...

Page 2: ...o ground after a duress key has been entered It is often used to trigger an alarm an auto dialer or a buzzer 12 Common Ground 13 Door Position Sensor Input N C normally close input terminal See door sensor wiring diagram to the right Always connect terminal 13 to ground if not in use 14 Output 1 Inhibit N O normally open input terminal Both relay 1 user keys and egress button cannot activate outpu...

Page 3: ... two KPX 100 with cross wire connections on the output 1 inhibit 14 and inter lock control output 15 terminals Connect the common ground terminals 12 of the two keypads Use N O relay output for fail secure locking and N C output for fail safe locking An inter lock system prevents both doors from being open at the same time for a more secure entry Keypad Back Lighting jumper selected 1 Backlit The ...

Page 4: ...8 digits of your choice followed by 0 5 To change the programming key press 0 and then 4 digits of your choice followed by 0 6 To create user keys for relay 1 and 2 press the relay number the user number and then 4 8 digits of your choice followed by Relay 1 can have 100 user keys relay 2 can have 10 user keys User keys must be the same length as the programming key if planning on using auto entry...

Page 5: ...ase user codes and programming code Must add programming code back after change 8 9 0 0 Sets the mode and clears all previously stored data and modes Single user mode assigns one user key per relay Multi User Mode Reset Only use to change modes will erase user codes and programming code Must add programming code back after change 8 9 0 1 Sets the mode and clears all previously stored data and mode...

Page 6: ...n the door is forced open Output through terminal 13 Correct Key Entry Tones 8 1 0 8 1 1 8 1 2 Keypad does not beep upon correct key entry Keypad beeps twice upon correct key entry Keypad beeps once upon correct key entry default User Key Entry Mode 8 2 0 8 2 1 Requires after user key is entered default Keypad does not require after user key is entered All user keys must match Programming key leng...

Page 7: ... 5 seconds the keypad will beep before output 1 activates Press and hold the egress button for 10 seconds the keypad will beep before output 1 activates Troubleshooting Symptom Possible Cause Solution Forgotten programming key Forgotten programming key 1 Disconnect the power supply 2 Move the DAP jumper from OFF to ON 3 Reconnect the power supply The keypad will start beeping 4 Move the DAP jumper...

Page 8: ...tion Record Loc Code Loc Code 00 50 01 51 02 52 03 53 04 54 05 55 06 56 07 57 08 58 09 59 10 60 11 61 12 62 13 63 14 64 15 65 16 66 17 67 18 68 19 69 20 70 21 71 22 72 23 73 24 74 25 75 26 76 27 77 28 89 29 79 30 80 31 81 32 82 33 83 34 84 35 85 36 86 37 87 38 88 39 89 40 90 41 91 42 92 43 93 44 94 45 95 46 96 47 97 48 98 49 99 ...

Page 9: ... support 216 518 9889 9 9 Document No 10579100 Rev 2 5 technical emxinc com EMX Industries Inc products have a warranty against defects in materials and workmanship for a period of two years from date of sale to our customer ...