Installation
1.
Connect power to terminals 1 and 2, 12-24 VDC/AC. The terminals are polarized.
2.
Connect the operator OPEN contacts to output 1 N.O. (5) and COM (4).
3.
Enter programing mode by pressing...
The orange LED will turn on.
0000 is the factory set programming key. At any time, you can enter the programming
key followed by * to enter programming mode.
You must enter programming mode to enter any codes or add any user keys.
0 0 0 0 *
Multi-User
(Factory default)
Single-User
4.
To enter Multi-user mode press…
8 9 0 1 #
Record user locations and codes for easier
editing in the future!
4.
To enter single user mode press…
8 9 0 0 #
5.
To change the programming key, press 0 and
then 4-8 digits of your choice followed
by #.
0 ? ? ? ? ? ? ? ? #
5.
To change the programming key, press 0 and
then 4 digits of your choice followed by #.
0 ? ? ? ? #
6.
To create user keys for relay 1 and 2,
press the relay number, the user number and
then 4-8 digits of your choice followed by #.
Relay 1 can have 100 user keys, relay 2 can
have 10 user keys.
User keys must be the same length as
the programming key if planning on
using auto entry mode.
6.
To create the user keys for relay 1 and 2,
press the relay number followed by 4 digits
of your choice. User keys are 4 digits in length.
Relay 1
Relay 2
1 ? ? ? ? #
2 ? ? ? ? #
7.
The output length and toggle mode can
be adjusted using the codes shown in the
tables.
Code 4 0 / 5 0 will change the output length – the time the door will remain unlocked.
Code 4 1 / 5 1 will change the output to toggle mode – the door will remain unlocked until a code
is re-entered.
Relay Output 1
Relay Output 2
4 0
1-999
# 5
0
1-999
#
4 1
Toggle Mode
5
1
Toggle Mode
8.
To exit programming mode press…
*
TIP:
TIP: