Page 1: ...ICS KP14 Instruction Manual 01850 53 000 Issue 3 19 January 2021 LASERMET ICS KP14 INSTRUCTION MANUAL ACCESS KEYPAD WITH DUAL CHANNEL OVERRIDE TIMER...
Page 2: ...Installation 6 5 Wiring 8 5 1 Connecting to Lasermet ICS Control Panels 9 5 2 Internal Door Release 10 5 3 Connecting to Door Lock 11 5 4 Connecting two or more Keypads to one ICS 11 6 Fixing 12 6 1...
Page 3: ...nd standards and found to comply Lasermet certifies that this product complies with the basic requirements for health and safety as provided by the following directives and standards Directives Low Vo...
Page 4: ...o tamper with the parts open them or use them outside of the parameters contained herein The units are only designed to be fixed to surfaces using their inbuilt fixing holes They must not come into co...
Page 5: ...ride timer function is of a dual channel cross checked configuration and is designed to achieve a safety performance level of PL e to EN13849 when correctly wired to a suitable interlock system Laserm...
Page 6: ...proximately 1 2m up from floor level During installation wired connections will need to be made from the ICS KP14 to the Interlock Control System and possibly the door interlock switch and magnetic do...
Page 7: ...nce all the holes have been made secure the rear cover as shown in the diagram below Feed the cables through the hole in the centre of the rear cover Make the electrical connections before attaching t...
Page 8: ...shbutton switch to activate the keypad remotely When the button is pressed the keypad activates its outputs according to the programmed settings as though the correct code had been entered on the keyp...
Page 9: ...ride when the keypad is operated The jumper link J6 OVERRIDE CONTROL is removed so that the ICS 6 only indicates that an override is active but isn t actually overridden itself The two override output...
Page 10: ...A terminal of J6 goes to the OR A terminal of J7 inside the ICS 6 and the other B terminal of J6 goes to the OR B terminal of J7 inside the ICS 6 Make sure the connections are not transposed the OR A...
Page 11: ...s on J5 and the adjacent NC terminal should then go to the positive connection of the lock see below This will enable the keypad to break the circuit to the lock thus releasing it For safety reasons e...
Page 12: ...ce the keypad has been locked to the wall a 5mm flat screwdriver is required to release the locking latch before it can be removed as shown below Ensure that the supply is turned off Insert the screwd...
Page 13: ...of the following choices by pressing the appropriate key on the keypad Change User Code Change Program Code Change Override Time Change Door Unlocked Time Enter Test Mode Exit and return to normal op...
Page 14: ...sh to disable the selected output for example to disable the Door Unlock output because there is no door lock simply program the selected time to 0 seconds If you make an invalid entry e g by entering...
Page 15: ...he correct user code has been entered and the Door Unlock output is active The keypad has an audible alarm which sounds while the door is unlocked OVERRIDE ON This message appears in red in the lower...
Page 16: ...A continuous sound will be made by the ICS to indicate that the system is overridden A rapid pulsed sound will be made by the keypad to indicate that the door is unlocked After a few seconds the Door...
Page 17: ...24VDC Current Consumption 25mA standby 150mA activated Size 160mm wide X 108mm high X 38 5mm deep Weight 200g All figures quoted are approximate Lasermet reserve the right to alter specifications with...
Page 18: ...vide a complete system We also supply equipment and consultancy covering all aspects of laser safety Full support design and installation is available from Lasermet please contact us for any queries F...