Handbuch-KnxSmartmeter-85A-en-3.odt, 2018-10-04
Seite 5 von 69
Connections
Voltage measurement input:
Cross section:
Input voltage:
Power frequency:
Current sensor input:
Cross section:
Ground terminal:
Cross section:
Max. cross section through
current sensor:
EIB / KNX Connection:
4 pol. screw terminal
0,33 ... 4 mm² / AWG 22 ... 12
max. 460Vrms
50Hz
3 x 3 pol. screw terminal
0.2 ... 4 mm² / AWG 24 ... 12
3 pol. screw terminal for functional earth,
internal bridged
0.2 ... 4 mm² / AWG 24 ... 12
25 mm² / AWG3
Connector Type 5.1
Installation
Scope of application:
Protection type:
Ambient temperature:
Protection class:
Over voltage category
for voltage input:
For use indoors
IP20
-5 °C
...
45°C
II
400Vrms / CAT IV
Housing
Type:
Width:
Dimensions:
Flammability:
DIN rail housing for 35 mm
rail
4 Units
70,0 x 89,6 x 62,9 mm (L x W x H)
UL94-V0
General
Certification:
Applicable standards for
CE-marking:
EIB/KNX certificated
Tested for safety in accordance with DIN EN
61010-1
Tested for EMC compliance in accordance with
DIN EN 50491-5
Meets requirements for housholds according to
DIN EN 50491-5-2 and for industrial according
to DIN EN 50491-5-3
Supplied
accessories
Current sensors:
SD-card
3 x current sensor (Rogowski-converter) with
each 1,5m Measurement line and centering clip
Micro SD card with adapter
Measurement
values
Current, Voltage, Active power, Reactive power, Active energy, Reactive
energy, Power factor, THD-U, THD-I, Unbalanced load, Zero current, Power
frequency, Power harmonics up to the 50th harmonics
Accuracy
class
Active energy according to
DIN EN 62053-21:
Starting current:
Max. current (Imax):
1 (1%)
2mA (rms value)
85A (rms value)
Enertex
®
Bayern GmbH – Ebermannstädter Straße 8 - 91301 Forchheim - Deutschland - [email protected]