Post-installation check
After the measuring instrument has been installed, perform the following checks:
• Is the measuring instrument damaged (visual check)?
• Does the measuring instrument correspond to the measuring point specifications such as process
temperature/pressure, ambient temperature, measuring range, etc.?
• Is the flange marking correctly aligned? (see Page 12)
• Have the flange screws been tightened up with the respective tightening torque?
• Are the measuring point number and labeling correct (visual check)?
• Is the measuring instrument adequately protected against rain and direct sunlight (see Page 68)?
Optimum mounting position
Positioning of the reflector on a floating roof:
• The upper edges of the reflector have to be
aligned horizontally.
• For slanted locations (e.g. dome-shaped
floating roof), the feet must be extended
accordingly.
Please contact Hauser for further
information.