3.3.2
Engineering hints
Orientation
• Recommended distance (1) wall -
outer edge
of nozzle:: ~1/6 of tank diameter (see Beam
angle on Page 16).
• Not in the centre (3), interference can cause
signal loss.
• Not above the fill stream (4).
• It is recommended to use a weather
protection cover (2) in order to protect the
transmitter from direct sun or rain. Assembly
and disassembly is simply done by means of a
tension clamp (see "Accessories" on Page 68).
L00-FMR53xxx-17-00-00-yy-009
Tank installations
• Avoid any installations (1), like limit
switches, temperature sensors, etc., inside the
signal beam (refer to beam angle (see "Beam
angle" on Page 16).
• It is essential that HiHi alarm is below the
blocking distance (BD) and the safety distance
(SD).
• Symmetrical installations (2), e.g. vacuum
rings, heating coils, baffles, etc., can also
interfere with the measurement.
Optimization options
• Antenna size: the bigger the antenna, the
smaller the beam angle, the less interference
echoes.
• Mapping: the measurement can be optimized
by means of electronic suppression of
interference echoes.
• Antenna alignment: refer to "optimum
mounting position".
• Stilling well: a stilling well can always be used
to avoid interference. The FMR532 with
planar antenna is recommended for stilling
wells with a diameter DN150 (6”) and larger.
• Metallic screens (3) mounted at a slope spread
theradar signals and can, therefore,
reduceinterference echoes.
Please contact Hauser for further
information.
L00-FMR53xxx-17-00-00-yy-010
Summary of Contents for Micropilot S FMR531
Page 4: ...Brief overview Micropilot S FMR531 with HART 4 20 mA 4 Endress Hauser ...
Page 87: ...Micropilot S FMR531 with HART 4 20 mA Technical data Endress Hauser 87 ...
Page 98: ...Micropilot S FMR531 with HART 4 20 mA Index 98 Endress Hauser ...
Page 100: ...www endress com worldwide BA207F 00 en 04 09 71093754 CCS FM SGML 6 0 ProMoDo 71093754 ...