The Micropilot is equipped with functions to suppress interference echoes. The user can activate
these functions. They ensure that interference echoes (i.e. from edges and weld seams) are not
interpreted as level echo.
Output
The Micropilot is commissioned by entering an empty distance E (=zero), a full distance F (=span)
and an application parameter. The application parameter automatically adapts the instrument to the
process conditions. The data points “E” and “F” correspond with 4mA and 20mA for instruments
with current output. They correspond with 0 % and 100 % for digital outputs and the display
module.
A linearization with max. 32 points, based on a table entered either manually or semi-automatically,
can be activated locally or remotely. This function provides a measurement in engineering units and
a linear output signal for spheres, horizontal cylindrical tanks and vessels with conical outlet.