14-7
Frequency command
Parameter
st
1 byte : 0
x
00
nd
2 byte : 0
x
04
setting data
output frequency *100
Ex) the case of output frequency command is 60.00Hz
Data 6000 transmit
st
1 byte : 0
x
17
nd
2 byte : 0
x
70
16bit CRC generation
The step of CRC generation is as follows:
1. All of 16-bit register is 1.0
x
ffff
2. The exclusive OR of 16-bit register and 8-bit register.
3. Shift right side 1bit 16-bit register
4. If the result of step 3 is 1, exclusive OR 16-bit register and 0xa001.
5. Execute 8 times step 3 and step 4.
6. Execute step 2¡6 until data completion.
7. Exchange the step 6 result of higher 8bit and lower 8bit.
Ex)
The case of D01 output frequency reading.
Byte 1
Byte 2
Byte 3
Byte 4
Byte 6
Byte 7
Commun-
ication
number
Command
Parameter
Parameter number
0
x
01
0
x
03
0
x
01
0
x
01
0
x
00
0
x
01
ENDA E-100
INSTRUCTION MANUAL