3
E0503 148 × 210 mm
3. If the outdoor temperature information disappears from the display,
follow again the same steps for capturing the signal.
4. We recommend to place the sensor to the Northern side of the house.
In the built-up areas the transmission distance may rapidly decrease.
5. The sensor is resistant to the dropping water, however do not dispose
it to the persistent rain.
6. Do not place the sensor on the metal platforms, this may disturb the
signal transmission.
7. In case the low battery icon appears, change the batteries in the
sensor or in the weather station.
Changing the Channel and Attaching
Additional Sensors
1. By pressing shortly the CH button on the weather station choose the
required sensor‘s channel - 1, 2 or 3. Then hold the CH button, the
icon starts flashing.
2. Remove the battery cover at the rear side of the sensor and insert the
batteries (2×AA).
3. Set the required channel No. of the sensor - 1, 2, 3, by repetitive
pressing the CH button - depending on how many time the button is
pressed, the required channel will be set and the LED will be flashing
1×, 2× or 3× in row. The information from the sensor will be retrieved
within 3 minutes.
4. In case the signal from the sensor has not been found, remove the
batteries from the weather station and repeat all the steps again.
Displaying the Information from the Sensor
To display the information from the sensor 1, 2, 3, press repeatedly the
CH button on the weather station.
For the continuous displaying of the information form all the sensors press
several time the button CH, the icon I will appear.
The value from each sensor will be shown for the time of 6 seconds.
To cancel the continuous displaying, press the CH button again and the
icon I will disappear.
Radio Controlled Clock (DCF77)
The radio signal is spread by the radio waves (77.5 kHz) to the places in
the range of 1500 km from Frankfurt am Main in Germany. This radio clock
signal automatically takes into the account the daylight saving time (DST),
leap-years and the date changes.
After registration of the remote sensor, the weather station automatically
starts capturing the DCF77 signal. This lasts for 10 minutes.
During capturing the signal no information on the display will be updated
and the button will not be working (except the SNOOZE button).
During capturing the signal the following icon will be flashing .
When the signal will be captured - the icon will stop flashing and the
following icon will be displayed and the current time will be displayed.
The signal has not been found - the icon disappeared.
To initiate the DCF77 signal capturing process again, hold the MEM
button for 3 seconds.
To cancel the DCF77 signal capturing process, press the MEM button again.
DCF77 signal will be synchronized daily from 2.00a.m. till 5.00a.m. o‘clock.
To capture the signal under the normal circumstances (in the save
distance from the sources of interference such as TV sets, PC screens) it
lasts several minutes.
In case the clock does not capture this signal, proceed the following steps:
1. Relocate the weather station into another place and repeat the DCF77
signal capture steps.
2. Check the distance of the clock from the sources of interference such
as PC screens TV sets. The distance should be kept at least from 1.5 to
2 meters. Do not put the weather station when capturing the signal
close to the metal doors, window frames or any other metal construc-
tions, objects (washing machines, laundry dryers, refrigerators, etc.).
3. Within the iron-reinforced concrete construction premises (base-
ments, high building, etc.) depending on the conditions, the DCF77
signal reception is weaker. In the extreme cases place the weather
station close to the window into the direction towards the transmitter.
The quality of the DCF77 radio signal is influenced by the fol-
lowing factors:
• thick walls and insulation, basement and underground premises
• inappropriate local geographic conditions (difficult to estimate)
• atmospheric disorders, storms
• radio interference not suppressed electrical appliances, TV sets and
PCs placed close to the radio receiver DCF77
Manual Time and Date Setting
1. Hold the MODE button.
2. With buttonsc / set the 12/24 time format – time zone - hour – minute
– year – data format – date - calendar language (E – English, G – German,
F – French, S – Spanish, I – Italian) - °C/°F temperature format – activation
(ON) or deactivation (OFF) of signal DCF77 capturing.
3. To move from one to another value use the MODE button.
4. For faster value setting hold the / button.
The Pressure Trend (Weather)
The arrow in the A field indicates the pressure trend (the weather
progression)
indication on
display
The Pressure
Trend (Weather)
Ascending
Constant
Descending
The Moon Phases
The moon phases are displayed in the C field.
The icons of the main phases are as follows:
1-New Moon, 2-Leaving New Moon, 3-First Quarter, 4-Waxing Moon,
5-Full Moon, 6-Waning Moon, 7-Last Quarter, 8-Approaching New moon
Displaying the Minimal/Maximal Temperature
and Humidity
By pressing the MEM button, the maximal and minimal measured tem-
perature and humidity values will be step by step displayed.
By holding the MEM button for 2 seconds the values will be deleted
from the memory.
Setting the Alarm Clock Time
The weather station enables to set two alarm times. Press the MODE button
several times until the alarm time appears.
Choose the alarm clock No. 1 (A1) or No. 2 (A2) by pressing the MODE
button.
By holding the MODE button and with the / the buttons set the
alarm time.
After setting the hour and minute (to move from one to another value
use the MEM button) press the / button to activate/deactivate the
alarm clock.
The icon of sound G will be displayed. The alarm number will be displayed
in the middle of the bell icon - the alarm clock is activated. It is possible
to activate the both alarm clocks at the same time, each must be set to
a different time.
Alarm Snooze and the Backlight (SNOOZE)
You can postpone the alarm sound about 5 minutes by pressing the
SNOOZE button.
The Alarm clock icon will be flashing.
To cancel the snooze function, press any button. The Alarm clock icon
will stop flashing.
If you do not want to use the snooze function, when alarm sounds press
any button except the SNOOZE button.
Summary of Contents for SNOOZE E0503