3 - 1
Section 3: Installing the 370XA
3.1
Site Requirements
3.1.1
Site requirements
Consider the following when choosing an installation site for the GC:
•
This gas chromatograph is designed to operate at
temperatures between -20 ºC (-4 ºF) and 60 ºC (140 ºF).
•
Install the GC as close as possible to the sample point but
allow for adequate access for maintenance tasks and
adjustments. The analyzer should also be installed to allow
easy access and viewing of the LOI.
•
Allow at least 10 inches (254 mm) on the right hand side of the
GC to permit access to the side portal hole where the field
terminations are made.
•
Allow a minimum of 10 inches (254mm) above the top of the
dome to facilitate access to the analytical module.
3.1.2
Mounting requirements
The 370XA can be mounted on a 4-inch pole or onto a wall using one
of the mounting kit options.
The pole or wall must be able to support at least 50 pounds (20 kg)
and withstand the forces applied when performing routine
maintenance, such as removing the oven enclosure dome.
3.2
Actions Upon Recent of GC
3.2.1
Unpacking
There are no special unpacking considerations.
Summary of Contents for Rosemount 370XA
Page 1: ...Revision A 7P00370 H01 April 2014 370XA Gas Chromatograph System Reference Manual ...
Page 32: ...370XA Gas Chromatograph System Reference Manual APRIL 2014 7P00370 H01 3 5 3 3 2 2 Dimensions ...
Page 137: ...System Reference Manual 370XA Gas Chromatograph 7P00370 H01 APRIL 2014 5 8 ...
Page 138: ...6 1 Section 6 Overhauling the maintainable module ...
Page 177: ...System Reference Manual 370XA Gas Chromatograph 7P00370 H01 APRIL 2014 6 40 Column 2 ...
Page 178: ...370XA Gas Chromatograph System Reference Manual APRIL 2014 7P00370 H01 6 41 Column3 ...
Page 179: ...System Reference Manual 370XA Gas Chromatograph 7P00370 H01 APRIL 2014 6 42 Column 4 ...
Page 182: ...370XA Gas Chromatograph System Reference Manual APRIL 2014 7P00370 H01 6 45 Sample Loop SL ...
Page 195: ...System Reference Manual 370XA Gas Chromatograph 7P00370 H01 APRIL 2014 7 8 ...
Page 198: ...370XA Gas Chromatograph System Reference Manual APRIL 2014 7P00370 H01 7 11 ...
Page 199: ...System Reference Manual 370XA Gas Chromatograph 7P00370 H01 APRIL 2014 7 12 ...
Page 200: ...370XA Gas Chromatograph System Reference Manual APRIL 2014 7P00370 H01 7 13 ...
Page 202: ...370XA Gas Chromatograph System Reference Manual APRIL 2014 7P00370 H01 7 15 ...
Page 204: ...370XA Gas Chromatograph System Reference Manual APRIL 2014 7P00370 H01 7 17 ...
Page 205: ...System Reference Manual 370XA Gas Chromatograph 7P00370 H01 APRIL 2014 7 18 ...
Page 206: ...370XA Gas Chromatograph System Reference Manual APRIL 2014 7P00370 H01 7 19 ...