Standard mating metal flange
•
A193 B8M Cl.2 / A4-70 bolt material
•
Friction coefficient of μ=0.16
Low strength bolt and non-metallic mating flange may require lower tightening torque.
Table 3-5: Torque Values for Process Seal Antenna, lb-ft (N-m)
Process connection size
Process connection rating
ASME B16.5
EN1092-1
JIS B2220
Class 150
Class 300
PN16
PN40
10K
20K
2-in./DN50/50A
29 (40)
52 (70)
26 (35)
29 (40)
18 (25)
37 (50)
3-in./DN80/80A
33 (45)
48 (65)
37 (50)
41 (55)
22 (30)
70 (95)
4-in./DN100/100A
59 (80)
52 (70)
37 (50)
74 (100)
26 (35)
74 (100)
6-in./DN150/150A
66 (90)
66 (90)
74 (100)
136 (185)
74 (100)
N/A
3.5
Mount the lens antenna
3.5.1
Mount on NPT threaded connections
Procedure
1. Apply anti-seize paste or PTFE tape on threads according to your site procedures.
Mechanical installation
Reference Manual
September 2022
00809-0100-4418
22
Emerson.com/Rosemount