Figure 7-23: Tank Bottom Projection
%
&
'
$
$
%
A. Level
B. Time
C. Enabled
D. Disabled
Prerequisites
The Tank Bottom Projection function is only available in Rosemount Radar Master Plus.
Procedure
1. Select
Configure
→
Level Setup
→
Advanced
.
2. Under
More Advanced Options
, select
Empty Tank Handling
.
3. In the
Tank Bottom Projection
list, select
Enabled
or
Disabled
.
4. If you enabled Tank Bottom Projection, then:
a) Set the Bottom Product Dielectric Constant.
b) Enter Maximum Projection Distance.
c) Enter Minimum Tank Bottom Echo Amplitude.
5. Select
Save
.
Related information
Bottom product dielectric constant
Enter the product dielectric constant for the product in the bottom of the tank.
Maximum projection distance
This defines the range in which the function operates. Enter the maximum distance from
the zero level (tank bottom). It is recommended to use the default setting.
Minimum tank bottom echo amplitude
Enter the minimum allowed amplitude for the echo from the tank bottom before this
function is activated. It is recommended to use the default setting.
Enable bottom echo visible when tank is empty
Enable the Bottom echo visible when tank is empty parameter if a bottom echo is visible
when tank is empty (i.e. for flat tank bottoms). The bottom echo will then be treated as a
Service and troubleshooting