Product data sheet
FieldQ
FieldQ
Copyright © Emerson. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website
www.emerson.com/fieldq or from your Emerson Automation Solutions - Actuation Technologies Center:
America’s:
+1 281 477 4100
Europe:
+36 22 53 0950
Asia/Pacific:
+65 67 77 8211
1.607.01 Rev. 2 Page 3 of 8
March 2019
Actuator Type
Pneumatic Interface (note 2)
QD
Double Acting
XX
Actuator suitable for Control modules
QS
Spring Return
QN
Actuator with NAMUR adaptation plate
Actuator Size
H1
Actuator with with 1/2" High flow plate
0040
Size 40
0350
Size 350
Insert Size Code (note 4)
0065
Size 65
0600
Size 600
S10
Square 10 mm (0.39")
S22
Square 22 mm (0.87")
0100
Size 100
0950
Size 950
S12
Square 12 mm (0.47")
S24
Square 24 mm (0.94")
0150
Size 150
1600
Size 1600
S14
Square 14 mm (0.55")
S27
Square 27 mm (1.06")
0200
Size 200
S16
Square 16 mm (0.63")
S36
Square 36 mm (1.42")
Connections
S17
Square 17 mm (0.67")
S46
Square 46 mm (1.81")
M
Metric Actuator (ISO 5211)
S19
Square 19 mm (0.75")
U
Imperial actuator (ISO 5211 / UNC)
Valve Flange Code
Spring Set (note5)
00
ISO 5211 (No Centerplate)
00
Double Acting
05
DIN3337 F05 (Centerplate / insert @ 45°)
01
SpringSet 01
04
SpringSet 04
07
DIN3337 F07 (Centerplate / insert @ 45°)
02
SpringSet 02
05
SpringSet 05
10
DIN3337 F10 (Centerplate / insert @ 45°)
03
SpringSet 03
06
SpringSet 06
12
DIN3337 F12 (Centerplate / insert @ 45°)
1x
Full stroke adjustment
14
DIN3337 F14 (Centerplate / insert @ 45°)
Temperature Range (note 1)
16
DIN3337 F16 (Centerplate / insert @ 45°)
ST
Standard Temp. Range -20° to +80°C (-4° to 176°F)
Visual Indication Code
HT
High Temp. Range -20° to +120°C (-4° to 248°F)
D
Standard Indicator
LT
Low Temp. Range -40° to +80°C (-40° to 176°F)
X
No Indicator
Future Expansion
Valve Mounting Code
A
Standard Yellow
I
In line with the pipe line
Assembly Code (note 3)
C
Cross line with the pipe line
CW
Clockwise rotation (Spring to Close)
CC
Counter-Clockwise rotation (Spring to Open)
Notes
1. Low and High temperature options are only available in combination with NAMUR plate option (QN)
2. The High Flow Plate includes the NAMUR Plate and can not be used with Control modules.
3. Assembly code CW is "Spring-to-Close", in combination with integrated modules.
Assembly code CC is "Spring-to-Open", in combination with integrated modules.
Failure mode of FieldQ with NAMUR plate depends on what solenoid is used.
4. See Insert Supplement for Additional Insert Options.
5. For the Full Stroke Adjustment option, replace the first "0" with a "1".
Example: Spring set "04" with full stroke will be "14", Spring set "03" with full stroke will be "13", etc.
Model String Configuration
Base Actuator
QS 0350
-
U 04 ST A CW
-
XX S27 0 D I
Actuator Type
Actuator Size
Connections
Spring Set
Temperature Range
Future Expansions
Assembly Code
Valve Mounting
Visual Indication
Valve Flange
Insert Size
Pneumatic Interface