Product data sheet
FieldQ
FieldQ
Copyright © Emerson. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website
www.emerson.com/fieldq or from your Emerson Automation Solutions - Actuation Technologies Center:
America’s:
+1 281 477 4100
Europe:
+36 22 53 0950
Asia/Pacific:
+65 67 77 8211
1.607.01 Rev. 2 Page 4 of 8
March 2019
Model String Configuration
Conventional Wired Control Module
QC41
-
U WP M S A 1
-
0040 I NS 0 IP 0 0
Control module
Conduit connections
Protection method
Control module options
Action
Future Expansions
Language
Bottom electrical entry
Top electrical entry
Pneumatic exhaust
Manual Control
Speed control
Mounting Options
IPT Device size actuator
Control module
IPT Device size for actuator:
QC41
Control module with 24 VDC pilot valve
0040
Q40 actuator
QC42
Control module with 115 VAC pilot valve
0065
Q65 actuator
QC43
Control module with 230 VAC pilot valve
0100
Q100 actuator
Connections
0150
Q150 actuator
M
Metric: Conduit: 2x M20x1.5 - Pneumatic: 1/4" BSP
0200
Q200 actuator
U
Imperial - Conduit: Top: 3/4"NPT; Bottom 1/2"NPT
Pneumatic entry 1/4"NPT
0350
Q350 actuator
0600
Q600 actuator
Protection method (note 1)
0950
Q950 actuator
WP
Weather Proof IP66/NEMA4X
1600
Q1600 actuator
P5
Flame Proof Ex d - ATEX, IECEx
0000
No IPT probe
F5
Explosion Proof XP or Flame Proof Ex d - FM & CSA
Mounting Options
B5
Flame Proof Ex d - INMETRO/Brazil
U
Uninstalled
Control module options (position feedback)
I
Installed/Tested to actuator
M
Mechanical switch
Speed control
G
Mechanical switch (Gold Plated)
NS
No Speed Control
O
3-wire prox. switch PNP
N1
Spring Return (1x throttle)
C
3-wire prox. switch NPN
N2
Double acting (2x throttle)
N
2-wire prox. switch (NAMUR)
Manual Control
H
2-wire prox. switch (20-140 VAC/10-140 VDC)
0
No Manual Control
Action
1
1x "Push&Lock", anodized aluminum
S
Single acting (Spring Return)
2
2x "Push&Lock", anodized aluminum
D
Double acting
3
1x "Push&Lock", Stainless Steel
F
Double acting Fail "In Last Position"
4
2x "Push&Lock", Stainless Steel
Future Expansions Code
Pneumatic exhaust
K
Standard Yellow
IP
IP65/NEMA4 rated exhaust
Language Code
IN
Non metalic exhaust / Check valve
1
English
Top conduit (Glands & Plugs, note 3)
2
Portuguese
0
Transport plug
1
Metal blind plug
Bottom conduit (Glands & Plugs, note 3)
0
Transport plug
1
Metal blind plug
Notes:
1. For more detailed information on hazardous area protection methods, certification agencies and suitable hazardous area see section
Selection guide Q-Series Control Module certifications
on page 2.
2. 2x Manual Control are only required in case of Double acting with Fail in Last Position function.
3. For QC41, QC42 and QC43: The Glands & Plugs options are a responsibility of the installer. Appropriate instructions can be found in the Installa-
tion Guide DOC.IG.QC41.1.
4. No separate pneumatic module required. Pneumatic function is integrated in the module.
5. For applications below -20°C (-4°F), the base actuator must be fitted with Low Temperature seals.
For use in atmospheres with a potential explosion hazard, the minimum temperature is -25°C / -13°F.