Configurations for open collector frequency outputs
(continued)
Table 3-1:
Cable
Cable re-
sistance
Cable
Pull-up
resist-
ance
Total
Maxi-
mum fre-
quency
Sink
Cable
voltage
drop
0.5
16.8
10.00
500
516.8
5000
0.046
0.780
1
33.6
20.00
500
533.6
5000
0.045
1.511
1.7
57.12
34.00
500
557.12
5000
0.043
2.461
6.5
218.4
130.00
500
718.4
1000
0.033
7.296
The 22 AWG wire characteristics:
•
Capacitance = 20 pF/ft or 20 nF/1000 ft (between two wires)
•
Resistance = 0.0168 Ohms/ft or 16.8 Ohms/1000 ft
•
Pull-up voltage = 24 VDC
3.3
Grounding meter electronics housing
The meter electronics should be internally grounded for intrinsically safe operations.
Connect a wire to the chassis ground lug installed inside the Transmitter Electronics
Enclosure as the primary ground. A secondary ground is located outside of the Transmitter
Electronics Enclosure (see ).
NOTICE
The internal grounding terminal shall be used as the primary equipment ground. The external
terminal is only a supplemental bonding connection where local authorities permit or require
such a connection. DO NOT connect digital grounds to the ground lugs.
Electrical installation
46
Gas Ultrasonic Flow Meter