Daniel models 3415, 3416 and 3417 meter specifications
(continued)
Table 1-1:
Daniel 3415, 3416 and 3417 meter specifications
Velocity range
•
100 ft/s (30m/s) with over-range)
•
125 fps (38 m/s) on some line sizes
•
Meter meets or exceeds AGA9 (2007) performance
specifications
Performance specifications
Table 1-2:
Models 3415 and 3416
AGA 9 / ISO 17089 Flow rate values (Metric units)
Meter size (DN)
200 to 600
Q
min
(m/s)
0.5
Q
t
(m/s)
3.048
Q
max
(m/s)
30.48
Models 3415 and 3416
AGA 9 / ISO 17089 Flow rate values (US Customary
Units)
Meter size (in)
8 to 24
Q
min
(ft/s)
1.7
Q
t
(ft/s)
10
Q
max
(ft/s)
100
Model 3417
AGA 9 / ISO 17089 Flow rate values (Metric units)
Meter
size
(DN)
200 to
600
750
900
1050
Q
min
(m/
s)
0.5
0.5
05
0.5
Q
t
(m/s)
3.048
2.591
2.29
CF *
Q
max
(m/
s)
30.48
25.91
22.86
CF *