background image

ELZAB Eco Print 

 

Operator's Guide 

31 

 

 

To enter the first 12 digits of an arbitrary bar code (BC), use the numeric keys 

..

. The last digit of the 

BC will be automatically calculated by the scale. Use the key 

to delete the last entered digit, if the blinking cursor 

is  in  the end  in  the  line. Move  the  cursor  to  the  left  and  to  the  right  with  the  keys 

and 

and  edit  the  digit 

highlighted by the blinking cursor with numeric keys. Keeping the key 

pressed clears all digits of the arbitrary bar 

code. To confirm setting an arbitrary bar code value, press the key 

. To quit Arbitrary Bar Code Input Mode without 

saving the changes, press the key 

 

It is possible to input the value of the arbitrary bar code from the bar code scanner connected to the scale. In 

Arbitrary Bar Code Input Mode, read the sample bar code with the scanner instead of entering its digits with numeric 
keys. Depending on the settings of the scanner, it will read the sample bar code immediately upon pointing the laser 
beam at it or after pressing the scan button on the scanner. Contact the system administrator to check how exactly 
your  scanner  is  programmed  to  operate.  The  sample  bar  code  transmitted  to  the  scale  (its  first  12  digits)  will  be 
indicated in the second line of the display of the scale. 

 

The entered arbitrary bar code can be used as long as an item is selected. Deselecting an item will discard the 

entered arbitrary bar code. The arbitrary bar code is not stored in the PLU data of an item, so selecting an item with an 
arbitrary bar code was entered sometime before will not automatically call up that arbitrary bar code, and the scale 
will print bar codes formed according to the structure programmed in its settings. 

 

2.9.10 Other Additional Functions 

 

 

Quick  access  keys  (refer  to  paragraph  1.3  Quick  Access  Keypad)  can  be  programmed  by  the  system 

administrator to execute other functions, e.g. to adjust the print contrast, to change the media type (label paper or 
receipt paper), to enable/disable label stripping sensor, change label format, turn on/off Prepacking Mode, etc. When 
executing some of these functions that modify scale parameters (e.g. print contrast or label format), the scale does not 
display any messages, thus to control the results of executing these functions it is required to perform a corresponding 
action (for the example given above – to print a label and check its contrast and format). 

 

Contact the system administrator to learn how quick access keys are programmed. Default value for all quick 

access keys is the same – “No functions”. 

 

2.10 Advertisement Text 

 

 

The system administrator can enable the automatic displaying of the advertisement text. If an operator has not 

been performing any actions with the scale for 5 minutes (i.e. has not been weighing products or pressing any keys), 
the scale will show in the lower line of the display a scrolling text programmed by the system administrator. Pressing 
any key or changing the weight on the platter/pan will automatically turn off Advertisement Text Mode. 

 

Illustration 22 

Summary of Contents for Eco Print

Page 1: ...ELZAB Eco Print DIGITAL LABEL PRINTING SCALE Operator s Guide Revision 7 Eng Modification Date 03 12 2015...

Page 2: ...tem Selection 18 2 1 6 Calling Up Items with Bar Code Scanner 18 2 2 Unit Price 18 2 2 1 Setting Unit Price with Numeric Keys 18 2 2 2 Setting Unit Price with Quick Access Keys 19 2 3 Entering Tare We...

Page 3: ...k DB Update Mode 32 2 11 3 Selected PLU Update Warning 33 2 11 4 Urgent Message 33 Part 3 Errors and Troubleshooting 34 3 1 Power Up Errors 34 3 1 1 Single Power Up Error 34 3 1 2 Multiple Power Up Er...

Page 4: ......

Page 5: ...d up with quick access keys if keyboard keys are properly programmed by the system administrator The scale has a built inmemory to store item informationandadditional textual information messages The...

Page 6: ...to input from the numeric and the quick access keypads the following data Secondary currency exchange rate up to 999 99 Item production date First 12 digits of an item bar code Automatic label printi...

Page 7: ...an 120 mm The scale should be configured by the system administrator to operate with the loaded format of label paper The scale can print weight items labels non weight items labels and up to 99 copie...

Page 8: ...thermal head of the printing mechanism Use the cleaning pen only Apart from the cleaning pen use spirit based cleaning solutions Before plugging the scale into the electric network make sure there is...

Page 9: ...o significant vibrations 1 2 Scale General View Illustration 1 above shows the main elements of the scales SHTRIH PRINT SHTRIH PRINT M andSHTRIH PRINT FI 1 Load Receptor hereinafter Platter 2 Scale Ho...

Page 10: ...1 45 otherwise the keys have numbers 46 90 Each quick access key can be set by the system administrator to do one of the following functions Call up an item by its code Call up an item by its PLU numb...

Page 11: ...the keys have numbers 19 36 Each quick access key can be set by the system administrator to do one of the following functions Call up an item by its code Call up an item by its PLU number Return a pre...

Page 12: ...ected tare the display tag NET turns on This key allows entering Non Weight Item Mode It is also used to select Price Editing Submode and Quantity Editing Submode in Non Weight Item Mode It is possibl...

Page 13: ...Mechanism product weight has been measured the display tag FIX is on and the calculated product cost value is not zero This key selects a preset item by its PLU number or its code depending on which...

Page 14: ...e to print a label if this option is enabled in the System Menu check it with the system administrator Min and Max values are indicated on the special sticker under the display PCS This display tag is...

Page 15: ...e foreseen by the manufacturer The platter should be equidistant for the sides of the scale housing The pan of SHTRIH PRINT PV model should hang loose and should not touch any foreign objects Turn on...

Page 16: ...ating for some reason press the key The display tag ZERO will turn on 1 7 Loading Paper in Printing Mechanism 1 7 1 Printing Mechanism SHTRIH PRINT SHTRIH PRINT M and SHTRIH PRINT FI Models To access...

Page 17: ...1 In SHTRIH PRINT PV model turn the lever 2 counter clockwise the thermal head will open see Illustration 12 Take off the fixing clamp from the take up unit 5 in Illustration 11 and 3 in Illustration...

Page 18: ...disable the label stripping sensor Contact the system administrator to have the label stripping sensor turned off Important Do not use sharp metal objects to fix any troubles with printing or feeding...

Page 19: ...g it entering unit price if the automatic printing is disabled the display tag AUTO is off When using automatic printing check with the system administrator if it is possible to select an item after w...

Page 20: ...the scale fails to find the requested code the scale will emit an error beep and display a message Item not found NOTE The PLU number and the item code number are different notions The PLU number is a...

Page 21: ...e the status of the display tag REG with the key before selecting a product Then select a product by pressing a corresponding quick access key 2 1 4 Overriding Unit Price of Selected Item Contact the...

Page 22: ...de If for some reason there is more then one item with the matching code in the scale database the scale will return the item with the smallest PLU number Important If a bar code read by the scanner h...

Page 23: ...ary to discard the previously entered tare weight value in order to enter a new tare weight value If tare weight value has been automatically selected from a PLU it will be discarded by deselecting th...

Page 24: ...memory of the scale and called in one of the ways described in paragraph 2 1 Selecting Items Thereby the scale will display the net weight of the called up item and turn on the tag NET Discarding a P...

Page 25: ...d label as well as its arrangement are programmed by the system administrator Important In all scale models except for SHTRIH PRINT PV design as a label has been printed and fed out of the printer it...

Page 26: ...everal label copies for a non weight item up to 99 follow the procedure below provided that a non weight item has been selected or the scale is in Non Weight Item Mode Press the key Then enter the req...

Page 27: ...then enable the Automatic Label Printing function Important If Prepacking Mode is enabled Automatic Label Printing function is operating differently from the described above refer to paragraph 2 8 Pr...

Page 28: ...repacking Mode is on press the key The GT label will be printed the contents of the GT memory will be cleared the display tag M will turn off and the scale will return to the normal operating mode NOT...

Page 29: ...e is different from the normal mode in the way how the grand totals memory and the automatic label printing functions operate in it These differences provide for a faster and easier packing of an item...

Page 30: ...to paragraph 2 1 Selecting Items or enter the required unit price refer to paragraph 2 2 Unit Price If the display tag REG is on turn it off with the key Press the key the scale will display a message...

Page 31: ...cale will return the current date value in the second line of the display as in Illustration 16 below To enter a new date value use the numeric keys Upon pressing a numeric key the digit being edited...

Page 32: ...ts a long beep the new value of the autoprinting threshold is invalid for example it exceeds Max To quit Autoprinting Threshold Program Mode without saving the changes press the key Automatic label pr...

Page 33: ...ter Secondary Currency Cost Equivalent Display Mode make sure that the cost of an item has been calculated Press a corresponding quick access key contact the system administrator the scale will return...

Page 34: ...roduction Date Program Mode The scale will display dashes instead of the production date value Confirm the clearing of the item production date with the key The scale will then use the current date fr...

Page 35: ...arbitrary bar code is not stored in the PLU data of an item so selecting an item with an arbitrary bar code was entered sometime before will not automatically call up that arbitrary bar code and the s...

Page 36: ...enable the mode of fast loading of PLUs and messages to the internal memory of the scale In Quick DB Update Mode the operation of the scale is locked and the scale displays a message as in Illustrati...

Page 37: ...it price code etc may have changed If this occurs contact the system administrator to know what data of the selected item has been modified 2 11 4 Urgent Message This function is specially designed to...

Page 38: ...ower Up Errors The scale runs a self test at power up If the unit is improperly installed out of order etc and the self test detects this the scale will display information about the detected errors a...

Page 39: ...ing recommendations To skip viewing the list of detected errors press the key the scale will proceed with displaying troubleshooting recommendations refer to paragraph 3 1 4 Troubleshooting Recommenda...

Page 40: ...marked with the tag M R System Menu or restrictions 4 Disable certain functions display a warning about such restrictions see Illustration 30 below and go to Main Mode in Error Type column of Table 1...

Page 41: ...the scale firmware has not been identified Contact the system administrator Scale not calibrated S B The scale is not calibrated Contact the system administrator Serial number not set S B The serial n...

Page 42: ...y tag ZERO would not turn on contact the system administrator Zero not set R There is load remaining on the platter pan it is impossible to set the weight value to zero The platter pan should be empty...

Page 43: ...on a special sticker under the display The scale displays dashes in the cost indicator and emits error beeps The second line of the display contains a message Cost out of range The cost value is too...

Page 44: ...disabled Contact the system administrator Returned to an attempt to save a new item unit price to PLU when this function is disabled Returned to an attempt to print a GT label in Grand Totals Mode wh...

Page 45: ...o the GT memory if no PLU is selected and it is not allowed to set manually unit price To perform these actions select an item first refer to paragraphs 2 9 2 Saving Unit Price to Scale PLU Memory 2 9...

Page 46: ...ot is clean refer to paragraph 1 7 Loading Paper in Printing Mechanism Printer head open The head of the printer is not closed Bring together the closing levers of the thermal head until you hear a cl...

Page 47: ...tem administrator Zero cost Calculated cost value is zero Enter unit price or select an item In Non Weight Item Mode enter quantity of the item in pcs Incomplete printing This error may occur if the l...

Reviews: