Preparatory measures for initial operation
© Elma GmbH & Co KG
BA/Elmaflame/GB/1107
15
5.2
Mounting of the unit top part
The preassembled unit top part is packed separately and must
be mounted onto the Elmaflame base unit. The protecting foil
should remain around the glass containers (serves as fracture
protection).
Required tools
•
1 fork wrench size 10 mm (or comparable, suitable tool).
•
1 fork wrench size 19 mm (or comparable, suitable tool).
C
A
A
B
D
Illustration 5.2. Correctly mounted and connected unit top part
1. Use the 4 cap nuts (A) to screw the unit top part to the 4
threaded bolts on the Elmaflame unit top (fork wrench 10
mm).
How to proceed
2. Remove the yellow screw cap (transport safety device) on
the reactor outlet (B).
3. Connect the gas hose to the reactor outlet by means of the
union nut (fork wrench 19 mm).
Caution!
Do not jam the
connection nut.
Then tighten the connecting nut by means of the fork
wrench. For this, hold the reactor at the filling duct with one
hand. A slight movement of the reactor is possible and
harmless because the reactor connection is elastic. Tighten
the screw connection fast to avoid leaks in the pressure
system.
4. Connect the gas hose of the burner hand piece to the outlet
on the top part (C).
The unit top part is movable to facilitate the removal of the glass
containers.
Summary of Contents for Elmaflame 140