Initial operation
© Elma GmbH & Co KG
BA/Elmaflame/GB/1107
23
If there is a leak, the display shows:
If the unit is leaky
Unit is leaking!
Repair the leak!
The leak must be found and repaired before the unit is
operated.
Check if the screw connections between gas hose and reactor
outlet and between gas hose and outlet at the top part are
correctly tightened; also check the screw connections at the
burner hand piece and at the filling ducts for electrolyte and
vapourizer liquid. When in doubt contact your supplier or the
manufacturer of the unit.
If there is no leak, the display shows:
If the unit is
leakproof
No leak
Continue
Confirm this programme step by pressing the key
(
Continue
)
at the operating panel.
The programme now carries out a signal buzzer test. The signal
buzzer is activated and the display shows:
Check signal buzzer
On!
Press key!
Finish checks
Press any operating key, the signal buzzer is switched off and
the unit is now ready for operation.
6.4
Selection of the burner nozzle
The Elmaflame units are delivered with a selection of nozzles of
different sizes.
Elmaflame 140: 0.5 mm (G25) – 1.0 mm (G19)
Allowed nozzle sizes
Elmaflame 240: 0.5 mm (G25) – 1.5 mm (G17)
Elmaflame 300: 0.5 mm (G25) – 1.8 mm (G15)
The use of larger nozzles is not allowed.
The use of smaller nozzles is possible without problem. Select
the suitable nozzle from the nozzle set depending on the
required soldering job and fasten it onto the conical tip of the
hand piece.