Preparatory measures for initial operation
16
BA/Elmaflame/GB/1107
© Elma GmbH & Co KG
5.3
Filling of the reactor with electrolyte solution
For the production of gas a certain amount of electrolyte
solution is required. When delivered, the unit is not filled with
electrolyte for reasons of safety.
The electrolyte is not included in the delivery volume and must
be purchased separately.
Electrolyte is a strong caustic solution!
Risk of heavy causticization on skin, mucous membranes and
eyes!
Risk of causticization of the mucous membrane caused by
inhaling of vapours!
Always wear protective gloves and goggles when handling
electrolytes to prevent causticization! Do not inhale the vapours!
Store open containers with electrolyte at a safe place and keep
them out of reach of unauthorized persons, in particular of
children.
CAUTION!
Please note! In order to avoid damages on the unit, use suitable
electrolyte and distilled water only!
If in doubt contact the manufacturer or your supplier for
information.
NOTE
Filling quantities
Electrolyte solution
Elmaflame 140
Elmaflame 240
Elmaflame 300
1.6 litre electrolyte
solution
- -
4.0 litre electrolyte
solution
+
0.1 litre distilled water
4.0 litre electrolyte
solution
+
0.1 litre distilled water
If the electrolyte solution must be produced from solid
potassium hydroxide (KHO) by the customer, proceed as
follows.
How to produce
electrolyte solution
Use the following substances only:
Prescription on the
production of
electrolyte
•
Potassium hydroxide (cookies or flakes – free of water):
KOH quality: KOH must be contaminated with max. 1.5%
potassium carbonate.
•
Distilled water
Summary of Contents for Elmaflame 140
Page 42: ......