M1EZ8 Installation and Programming
Page 59
[Effective w/Firmware 4.3.6]
This Control complies with the SIA CP-01 Control Panel Standard - Features for False Alarm Reduction
PROGRAMMABLE FEATURES, SHIPPING DEFAULTS, AND RECOMMENDED PROGRAMMING
* Programming at installation may be subordinate to other UL requirements for the intended application.
** Combined Entry Delay and Abort Window should not exceed 1 minute.
*** Feature is pre-defined in the panel software and may not be altered.
Required
Required
REQUIREMENT
Required
(programmable)
Allowed
Required Option
Required Option
(except for remote arm)
Required
(programmable)
Required Option
Required
(programmable)
Allowed Option
Required Option
Allowed
Required
(programmable)
Required Option
Required
Annunciate that no alarm was transmitted
Annunciate that a Cancel was transmitted
ALLOWABLE RANGE / PURPOSE
45 - 120 sec. (2 minutes) for full or auto
arming Shall not exceed 255 seconds
Individual keypads may be disabled
Only one restart during arming.
Away arm changes to Stay Arm
if there is no exit detected.
30 sec. to at least 240 sec.
(4 minutes) minimum **
May be disabled - by zone or zone type
15 sec. - 45 sec. **
Cannot be a 1+ or derivative of another
user. No duplicates with other user codes
Violation of a zone defined as Cross zone
requires verification by another zone
Programmable from 1 to 255 seconds.
For all non-fire zones,
shut down at 1 trip.
Depends on Panel and Sensors
Call waiting cancel prefix code may be
dialed on initial attempt ONLY.
Enabled - No
disable option
Enabled - No
disable option
SHIPPING
DEFAULT
60 Seconds
All Audible
Annunciators
Enabled
Enabled
30 Seconds
Enabled
30 Seconds
Disabled
Disabled
30 Seconds
Enabled
Disabled
Blank - Not
Programmed
4.2.5.1.2
4.2.5.4.1
CP-01 Std.
Par. #
4.2.2.1
4.2.2.2
4.2.2.3
4.2.2.5
4.2.3.1
4.2.5.1
4.2.5.1
4.2.6.1
& 4.2.6.2
4.3.1
4.3.1
4.3.2
4.3.3
4.5
Abort Annunciation ***
Cancel Annunciation ***
FEATURE
Exit Delay Time 1 & Exit Delay Time 2
Silent on Exit (Disable Exit Progress
Annunication - ie: Silent Exit)
Exit Time Restart
Auto Interior Off (Auto "Stay" Arm on
Unvacated Premises)
Entry Delay Time 1 & Entry Delay
Time 2
Comm Abort Time (Abort Window) for
Non-Fire Zones. 000 time = Disabled
Comm Abort Window Time - for Non-
Fire Zones
Duress (Individual User Code Option)
Cross Zoned (Zone Option)
Cross Zone Verify Time
Single Alarm Lockout (Swinger
Shutdown)
Fire Verified Zone Definitions (Fire
Alarm Verificatoin)
Call Waiting Cancel ***
Enabled
Enabled
RECOMMENDED
PROGRAMMING *
60 Seconds
All Audible Annunciators
Enabled
Enabled
At least 30 Seconds **
Enabled (all zones)
At least 15 seconds
Disabled
Enabled and two (or
more) zones programmed
Time based on walk path
in protected premises
Enabled
Enabled unless sensors
can self-verify
Depends on User Phone
Line
Appendix C - SIA CP-01 Compliance
WWW.DIYALARMFORUM.COM