M1EZ8 Installation and Programming
Page 5
[Effective w/Firmware 4.3.6]
Wiring & Hookup Diagram
-
ST
AT
U
S
UL Listed
Transformer
,
16.5VAC, 45VA.
Class II,
(ELK-TRG1640)
LI
N
E
SEI
Z
E
N.C.
N.O.
2200
Ohm
EOL
N.C.
N.O.
Zone
8
2200
Ohm
EOL
POW
E
R
Data Bus
-See Note in Manual
RED
BLACK
WHITE
GREEN
Keypad
+
Siren or Voltage
See Manual
Do Not Connect
to a Phone Line!
JP
1
2WI
R
E
SM
O
K
E
NOR
M
AL
ZO
N
E
8
JP3
For PLC Lighting
Interface
or M1EZ8MSI Main
Serial Port Interface
Aux Data Bus (J3)
For wireless receiver. Presently
works with GE-Caddx NX408E,
NX416E, or NX448E
Two-Way
Listen-In (J7)
Connects to
(M1EZ8TWI)
TELCO
Line
House
Phones
T
R
T1
R1
RJ31X Jack
(ELK-RJSET)
5
4
8
1
Demark
Block
splices
Yellow
Black
Red
Green
Green
Red Brown
PHONE LINE HOUSE LINE
TIP
RING
T1
R1
Z7
NEG
Z8
Compiles with FCC Part 68
Reg. Number: US:5K6AL03BELK-M1
Ringer Equivalence REN: 0.3B
Use USOC RJ-31X connector.
Complies with the limits for class B computer
devices in accordance with the specifications
of subpart J of part 15 of FCC rules.
For Voltage (open collector)
program option G26 to a Yes. Max.
Current Draw: 1 Amp If output is not
used, install a 2200 Ohm resistor to
avoid Output 2 trouble.
Out 3 - Relay
Programmable
General Purpose Dry Contacts
rated: 5Amps @ 12 - 28VDC
Select PLC Mode (JP2)
Selects single or bi-directional
PLC Transmissions
Terminating Jumper (JP3)
See manual for important information
about Data Bus Termination.
Testing of this system should be performed
regularly. Control panel specifications are subject
to change without notice. Figures not to scale.
12Volt - 5Ah min.
See UL requirements
for sizes and standby
times.
16
V XF
M
R
AC
AC
A
B
+1
2
V
KP
NE
G
OU
T
P
U
T
3
N/
O
N/
C
CO
M
Line Seize
LED is ON if Dialer
is in use (communicating)
Status LED
:1 blink = Normal Operation.
2 fast blinks = Bootloader mode.
4 fast blinks = Initializing EEPROM memory.
5 fast blinks = Memory/Operation overflow.
Power LED
is ON when AC Voltage is present.
Aux12VDC
Power Output
Protected by 1.25A PTC.
2200 Ohm EOL Resistors are part # ELK-ER2200
ELK-M1EZ8
J3
-
C
+
B
A
1
J7
1
2 W
A
Y
1 W
A
Y
-X1
0
-
JP2
J5
1
8
+12VDC Switched
Smoke Power
1.1 Amp PTC protected
4-Wire Smoke Detector
2200
Ohm
EOL
To Zone Input
U.L. Listed
EOL Supervision Relay
(ESL #204 or Equivalent).
(shown energized, contacts closed)
N.O. Alarm
Contacts
To Zone NEG
+VAUX
+VSMK
Grey
Ring Tip
T1 R1
Programmable Outputs (J16)
OUT 7 thru 16 are +12V switched positive
voltage outputs rated at 10mA max.
Connect optional ELK-M1RB Relay Board
for 8 general purpose relays.
J16
OU
T
16
OU
T
15
OU
T
14
OU
T
13
OU
T
12
OU
T
11
OU
T
10
OU
T
9
OU
T
8
OU
T
7
+
12V
NE
G
Re
d
Blac
k
Wh
ite
Gr
ee
n
Bro
w
n
Blue
Yello
w
Viole
t
Pink
Ta
n
Or
an
ge
Gr
ey
(Supervised)
+
A
L
ARM
-
OU
T
P
U
T
2
NEG
-
+
Connector J5
accepts either a 4 conductor modular cable for a PSC05 PLC
Lighting Interface OR an 8 conductor modular cable for a EZ8MSI Main Serial Port
Interface w/PSC05 pass through connector. (This connection not evaluated by UL)
PSC05
or
equiv.
PSC05 or
Equivalent
PC
Computer, OEM
component, etc.
RS-232
ELK-M1EZ8MSI
Main Serial Port Interface
J3
RS232
Serial
Cable
4 Conductor
Modular Cable
8 Conductor
Modular Cable
1
1
J1
From
EZ8
J2
Powerline
Interface
To J5
Connector
4 Conduc
tor
Modular C
able
OR
1
Note: Test battery regularly with
ELK-BLT Battery Life Tester.
Replace every 3-5 years
BATTE
RY
RE
D
BLK
Zone
7
-
+
+
-
(Sold separately)
12V
Battery
Yellow
Green
Red
Black
4 conductor modular (standard) phone
cord for PLC Lighting (not supplied).
End view
Yellow
Green
Red
Black
1
1
8 Conductor Cat5 cable from EZ8MSI Main Serial Port Interface.
End view
Brn/Wht
Wht/Brn
Grn/Wht
Wht/Blue
Blue/Wht
Wht/Grn
Org/Wht
Wht/Org
1
Wht/Org
Org/Wht
Wht/Grn
Blue/Wht
Wht/Blue
Grn/Wht
Wht/Brn
Brn/Wht
1
083005
ELK
PRODUCTS, INC.
HILDEBRAN, N.C., 28637, USA
Do not connect to switched outlet.
Out 2 - Alarm
(Siren or Voltage)
Connect a UL Listed siren or bell.
Default is Siren Min. 15 watt
(4-16 Ohm) speaker ELK-SP30
or equiv.
NOTE: Maximum continuous current drain from
+VAUX, +12VKP, +VSMK, and J16 combined must
not exceed 1 Amp (2.5 Amps in alarm)
N.C.
N.O.
2200
Ohm
EOL
N.C.
N.O.
Zone
6
2200
Ohm
EOL
Z5
NEG
Zone
5
Z6
N.C.
N.O.
2200
Ohm
EOL
N.C.
N.O.
Zone
4
2200
Ohm
EOL
Z3
NEG
Z4
Zone
3
N.C.
N.O.
2200
Ohm
EOL
N.C.
N.O.
Zone
2
2200
Ohm
EOL
Z1
NEG
Zone
1
Z2
1
1
RS232 Serial Port Cable (9 pin male
to 9 pin female) Max. length = 50 ft.
Pin 2 < to > 2
Pin 3 < to > 3
Pin 5 < to > 5
2-Wire
Smoke
Detector
680 Ohm EOL
Zone 8 can be configured as a 2-wire smoke zone. Set JP1 to "2
WIRE SMOKE" and use 680 Ohm EOL resistor, part # ELK-ER680
Use Only Compatible Detectors:
System Sensor: 2WTA-B, 2WTR-B, 2100, 2100T
GE: 429AT, 521BXT, 521B.
Hochiki America: SLK-835.
Detection Systems: DS250, DS250TH, DS282, DS282TH,
DS282THS, DS282THC.
Maximum Number = 20 Do not mix models.
2-Wire Smoke Circuit
-
+
NEG
Z8
Sealed Lead Acid
Battery
(ELK-1250)
N ot e : S e c on da r y phon e l i ne s ur ge
suppr ession devices ( ELK-95 0) are
recommended for areas prone to transient
or lightning strikes.
WWW.DIYALARMFORUM.COM