G13:_ _ _ _ _ _ _ _
r
Common To Area1
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
Menu 07 - Global System Definitions
(continued)
Global Sys Definitions
Description of Option
Any of the Areas 2 thru 8 may be made common to Area 1. The result is: Area 1 cannot
be armed until all its common areas are armed. Once armed, Area 1 will disarm if any
common area becomes disarmed. This is good for lobbies or vestibules shared by two or
more businesses. Each business must have their own area keypad.
NOTE: If you want
Area 1 to automatically arm when all its common areas become armed, use a
Whenever/And/Then rule from the RP software to do this.
Changes the Burglar Yelp sound on outputs 2 to a pulsing Buzzer sound. Default is No.
NOTE: When connecting 8 Ohm speakers, do not exceed an 4 Ohm total load.
Options G15 thru G25 are not used.
Allows Output 2 to be converted from a siren driver into a voltage only output. If set to
“No” the control produces alarm sounds for use with 8 Ohm speakers. If set to “Yes” the
control will p12 Volts for use with self-contained sirens or bells. Default is No.
Ordinarily, Outputs 1 & 2 activate immediately on alarms. However, Output 2 can be time
delayed up to 255 seconds. Using Output 1 strictly for interior sounders and Output 2 for
outside sounders, a false alarm will be heard inside first, giving the user time to disarm
before any outside sounders are activated. A “good neighbor” feature. Default is 000.
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
G26: =No
r
Out2 Voltage Out
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
G27:=000secOut2
r
Delay Turn-On
G14:=No Out2
r
Chg YelpToBuzzer
WWW.DIYALARMFORUM.COM