M1EZ8 Installation and Programming
Page 57
[Effective w/Firmware 4.3.6]
“Reset” Attribute
The letter(s) displayed in Reset column indicate what condition(s) it takes to
clear an event once it has been activated.
For example: the letters TMC indicate the event will reset when the output
timer ends, or when manually turned off, or when a valid user code is
entered, whichever comes first.
NOTE:
The reset attributes are shown only for informational purposes. They are set
by the factory and cannot be altered.
N (0)
Event follows the activation
T (1)
Event clears when output timer ends
M (2)
Event clears when manually turned off
C (4)
Event clears upon User Code entry
A (16)
Event clears upon Arming
D (32)
Event clears upon Disarming
B (64)
Event clears almost immediately “Blip”
F (128) Event toggles with each activation
1251 = Area 1 Chime Mode
N
1252 = Area 2 Chime Mode
N
1253 = Area 3 Chime Mode
N
1254 = Area 4 Chime Mode
N
1255 = Area 5 Chime Mode
N
1256 = Area 6 Chime Mode
N
1257 = Area 7 Chime Mode
N
1258 = Area 8 Chime Mode
N
1259 = Area 1 Chime Alert
B
1260 = Area 2 Chime Alert
B
1261 = Area 3 Chime Alert
B
1262 = Area 4 Chime Alert
B
1263 = Area 5 Chime Alert
B
1264 = Area 6 Chime Alert
B
1265 = Area 7 Chime Alert
B
1266 = Area 8 Chime Alert
B
1267 = Entry Delay Active
N
1268 = Area 1 Entry Delay
N
1269 = Area 2 Entry Delay
N
1270 = Area 3 Entry Delay
N
1271 = Area 4 Entry Delay
N
1272 = Area 5 Entry Delay
N
1273 = Area 6 Entry Delay
N
1274 = Area 7 Entry Delay
N
1275 = Area 8 Entry Delay
N
1276 = Exit Delay Active
N
1277 = Area 1 Exit Delay
N
1278 = Area 2 Exit Delay
N
1279 = Area 3 Exit Delay
N
1280 = Area 4 Exit Delay
N
1281 = Area 5 Exit Delay
N
1282 = Area 6 Exit Delay
N
1283 = Area 7 Exit Delay
N
1284 = Area 8 Exit Delay
N
1285 - Area 1 Exit Delay Expires
N
1286 - Area 2 Exit Delay Expires
N
1287 - Area 3 Exit Delay Expires
N
1288 - Area 4 Exit Delay Expires
N
1289 - Area 5 Exit Delay Expires
N
1290 - Area 6 Exit Delay Expires
N
1291 - Area 7 Exit Delay Expires
N
1292 - Area 8 Exit Delay Expires
N
1293 = Automatic Closing
B
1294 = Early Closing
B
1295 = Closing Time Extended
B
1296 = Fail to Close
B
1297 = Late to Close
B
1298 = Keyswitch Closing
B
1299 = Duress
B
1300 = Exception Opening
B
1301 = Early Opening
B
1302 = Fail to Open
B
1303 = Late to Open
B
1304 = Keyswitch Opening
B
1305 = Area 1 Closing Ring Back
B
1306 = Area 2 Closing Ring Back
B
1307 = Area 3 Closing Ring Back
B
1308 = Area 4 Closing Ring Back
B
1309 = Area 5 Closing Ring Back
B
1310 = Area 6 Closing Ring Back
B
1311 = Area 7 Closing Ring Back
B
1312 = Area 8 Closing Ring Back
B
1313 = Access Keypad 1
TM
1314 = Access Keypad 2
TM
1315 = Access Keypad 3
TM
1316 = Access Keypad 4
TM
1317 = Access Keypad 5
TM
1318 = Access Keypad 6
TM
1319 = Access Keypad 7
TM
1320 = Access Keypad 8
TM
1321 = Access Keypad 9
TM
1322 = Access Keypad 10
TM
1323 = Access Keypad 11
TM
1324 = Access Keypad 12
TM
1325 = Access Keypad 13
TM
1326 = Access Keypad 14
TM
1327 = Access Keypad 15
TM
1328 = Access Keypad 16
TM
1329 = Access, Any Keypad
TM
1330 = Keypad Beep Area 1
N
1331 = Keypad Beep Area 2
N
1332 = Keypad Beep Area 3
N
1333 = Keypad Beep Area 4
N
1334 = Keypad Beep Area 5
N
1335 = Keypad Beep Area 6
N
1336 = Keypad Beep Area 7
N
1337 = Keypad Beep Area 8
N
1338 = Area 1 Exit Error
N
1339 = Area 2 Exit Error
N
1340 = Area 3 Exit Error
N
1341 = Area 4 Exit Error
N
1342 = Area 5 Exit Error
N
1343 = Area 6 Exit Error
N
1344 = Area 7 Exit Error
N
1345 = Area 8 Exit Error
N
1346 = Audio Amplifier Status
TMC
1347 = Control Power Status
N
1348 = Light
N
1349 = Dark
N
1350 = Security (Day) Alert
TMC
1351 = Dialer Abort
B
1352 = Dialer Cancel
B
1353 = Dialer Auto Test
B
1354 = Local Programming Begin
N
1355 = Local Programming End
B
1356 = Keyswitch Security Alert
TMC
1357 = Event Log is 80% Full
N
1358 = Telephone Line Is Ringing
B
1359 = Telephone Line Seized Status T
1360 = Telephone Line Hook Status
T
1361 = Telephone Local Access
T
1362 = Telephone Remote Access
T
1363 = Remote Programming Start
N
1364 = Remote Programming Stop
B
1365 = AC Fail Tbl - Power Supv Zn N
1366 = Low Batt Tbl - Pwr Supv Zn
N
1367 = System Start Up
B
1368 = Control Low Volt Shutdown
N
1369 = RF Keyfob Button 1
B
1370 = RF Keyfob Button 2
B
1371 = RF Keyfob Button 3
B
1372 = RF Keyfob Button 4
B
1373 = RF Keyfob Button 5
B
1374 = RF Keyfob Button 6
B
1375 = RF Keyfob Button 7
B
1376 = RF Keyfob Button 8
B
1377 = Lost Serial Port Exp Tbl
N
1378 = Rule Triggered Voice Dial
B
1379 = Dialer Report Cleared
B
1380 = Central Station Kissoff
B
1381 = Transmitter Supervision Loss N
1382 to 2000 = No Event/Not Used
Appendix A - Event Codes (cont.)
2001 = Automation Control 1
TF
~
2032 = Automation Control 32
TF
2033 to 3000 = No Event/Not Used N
3001 = F1 Key on Keypad 1
F
3002 = F2 Key on Keypad 1
F
3003 = F3 Key on Keypad 1
F
3004 = F4 Key on Keypad 1
F
3005 = F5 Key on Keypad 1
F
3006 = F6 Key on Keypad 1
F
3007 to 3012 = F1 to F6 on KP 2
F
3013 to 3018 = F1 to F6 on KP 3
F
3019 to 3024 = F1 to F6 on KP 4
F
3025 to 3030 = F1 to F6 on KP 5
F
3031 to 3036 = F1 to F6 on KP 6
F
3037 to 3042 = F1 to F6 on KP 7
F
3043 to 3048 = F1 to F6 on KP 8
F
3049 to 3054 = F1 to F6 on KP 9
F
3055 to 3060 = F1 to F6 on KP 10
F
3061 to 3066 = F1 to F6 on KP 11
F
3067 to 3072 = F1 to F6 on KP 12
F
3073 to 3078 = F1 to F6 on KP 13
F
3079 to 3084 = F1 to F6 on KP 14
F
3085 to 3090 = F1 to F6 on KP 15
F
3091 to 3096 = F1 to F6 on KP 16
F
3097 = F1 Key, Any KP Is Pressed
B
3098 = F2 Key, Any KP Is Pressed
B
3099 = F3 Key, Any KP Is Pressed
B
3100 = F4 Key, Any KP Is Pressed
B
3101 = F5 Key, Any KP Is Pressed
B
3102 = F6 Key, Any KP Is Pressed
B
3103 = Any KP Key Is Pressed
F
3104 to 4000 = No Event
4001 to 4208 = Zone State 1 to 208
T
4209 to 5000 = No Event
5001 to 5208 = Bypass State 1 to 208T
5209 to 6000 = No Event
6001 to 6208 = Alm Memory 1 to 208 T
6209 to 7000 = No Event
7001 to 7208 = Output State 1 to 208 N
7209 to 8000 = No Event
8001 thru 9999 = No Event
Event Description
Reset
Event Description
Reset
Event Description
Reset
WWW.DIYALARMFORUM.COM