M1EZ8 Installation and Programming
Page 22
[Effective w/Firmware 4.3.6]
Menu 01 - Bus Module Enrollment
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
01-Bus Module
Enrollment
r
Bus Module Enroll
Description of Option
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
Enrolling
Bus Modules
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
XX Bus Modules
Enrolled, Edit
r
Press the RIGHT arrow key to select this menu and automatically start the bus enrollment
process. ALL data bus devices which are presently connected to the data bus should
become enrolled.
The enrollment process only takes a few seconds. Once complete, this summary screen
will appear displaying the total number of bus modules that were found and enrolled.
To
edit and/or view the devices individually, press the RIGHT arrow key one time.
Each enrolled keypad/device can be viewed one by one. The first device will always be
Keypad 1 with a T1 (for type 1) and Addr=01 (for address 01). As explained below,
different kinds of devices can be identified by their device “Type”. Pressing the Up or Down
arrow keys will scroll through each enrolled device.
If a device is removed from the data bus, it should be removed by repeating the enrollment
process. The control will only enroll the devices that are connected. It will remove any
previously enrolled devices that it does not see.
After the last device is reviewed, the next press of the Up arrow key moves to the “End
Enrollment” screen which once again displays the total number of devices enrolled.
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
Keypad
T1
b
Addr=01
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
Keypad
T1
b
Addr=02
lr
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
123456789012345678901234567890121234
End Enrollment
0x Bus Modules
NOTE: Every data bus device: Keypad, Input (Zone) Expander, Output Expander, etc. MUST have a unique
address within its type. This menu is then used to enroll the device into the system. SEE DETAILS BELOW:
DATA BUS DEVICE TYPES AND ADDRESSES:
Each data bus device is a specific “Device Type”. Keypads are TYPE
1, Input (Zone) Expanders are TYPE 2, Output Expanders are TYPE 3, Serial Port Expanders are TYPE 5. Any new
devices designed will be assigned a Device Type. Every data bus device MUST have a unique “Address” setting within
its type. Valid Input Expanders addresses are 2 to 13, Output Expander addresses are 1 to 13. The address determines
the starting and ending zone or output numbers for that expander. See chart below:
Addr Input Exp
Output Exp
Addr
Input Exp
Output Exp.
Addr
Input Exp
Output Exp.
1 = N/A (main bd) Outputs 1-16
6 = Zone 81-96
Output 65-80
11 = Zone 161-176
Output 161-176
2 = Zone 17-32
Output 17-32
7 = Zone 97-112
Output 97-112
12 = Zone 177-192
Output 177-192
3 = Zone 33-48
Output 33-48
8 = Zone 113-128
Output 113-128
13 = Zone 193-208
Output 193-208
4 = Zone 49-64
Output 49-64
9 = Zone 129-144
Output 129-144
5 = Zone 65-80
Output 65-80
10 = Zone 145-160
Output 145-160
INPUT AND OUTPUT EXPANDER ADDRESSES:
Locate the bank of four white (DIP) switches along the top edge of the
board. Each switch has a position of Off or On (0 or 1) and a binary value (1, 2, 4, 8). The addition of the binary values
(sum total) for the switches set to the On position determines the data bus address. For example: Data bus address 5
is set by placing switches 1 and 4 to the On position (1 + 4 = 5). All other switches must be in the down or Off position.
KEYPAD ADDRESSES:
All keypads are factory set to address 1. Valid addresses are 1 to 16. The first keypad on the
system (Keypad 1) is automatically enrolled upon power up. Each additional keypad must be assigned a unique
address and then manually enrolled from “Menu 1 - Bus Module Enrollment”. To set the address on a keypad do the
following:
1. Hold down a key while applying power OR press and hold the (Asterisk) “ * ” and F5 keys for 5 seconds.
2. Press the F1 key, then use the UP or DOWN arrow keys to set the desired address number.
3. Press the EXIT key when done.
NOTE: If a device is removed from the data bus, it should be un-enrolled to prevent a trouble. To replace a
defective device, set the address to the same value as the old unit and initiate the Bus Enrollment process.
Press RIGHT arrow key to select this menu. Press UP or DOWN arrow keys to select
another menu. The ELK key backs up one menu level. To exit press the * or Exit key.
WWW.DIYALARMFORUM.COM