60
English
11.3.3 Oil level check
For your information :
The paragraph below describes the procedure for checking the oil on a Honda
GX270 (GZC 1000). The B&S Vanguard 6.5 HP (GZC750) follows a similar
procedure.
• Place the machine on a flat surface.
• Disengage the engine and leave it for a while to allow the oil to seep back to the oil sump
(approx. 5 minutes).
• Remove the front weights from the machine to provide better access to the oil drainage plug
and oil filler cap.
• With a clean cloth, clean the area around the filler cap. Refer to the ‘General Description’
under § 6.2 Main machine parts (page 7) for possible positions of the oil drainage and drain
plugs.
For your information :
There are 2 oil drainage plugs and 2 oil filler caps on the motor. Only the oil
drainage plug and the oil filler cap on the operator side are used on this machine
(best access)!
Oil filler cap
oil drainage plug
• Remove the filler cap with the dipstick attached
to it from the crankcase.
Summary of Contents for GZC 1000
Page 1: ...GZC 750 GZC 1000 M A N U A L...
Page 86: ...86 English...
Page 91: ...91 English...
Page 92: ......