Appendix
2: ELCORplus version for Zone 2
196
given in paragraph 7 of this Annex.
The connection of the external power supply is described in section 8.3.
6.3 Plug-in modules - changes in use
The device has not place for SLOT 3. The change occurs in modules installed in SLOT 1, SLOT 2
and SLOT 4.
New modules S1N-COM1, S1N-2AI and S1N-2AO are intended for SLOT1 and SLOT 2, which
are functionally identical to similar intrinsically safe modules but their signals are output to the
SLOT 1 terminal block, resp. SLOT 2 are not intrinsically safe and can be connected to common
devices whose electrical parameters are in accordance with the parameters of these modules.
Other types of power supply modules are intended for SLOT 4.
trade name of the
module
module designation on the
label
name
instalation
S0-MIE
Indexer Module
Interface for mechanical
indexer ELGAS (only for
ELCORplus indexer for Zone 2)
SLOT 0
S0-SCR
SCR Module
Interface for SCR encoder of
gas meters
S0-NAM
NAMUR Module
Interface for NAMUR encoder
of gas meters
S0-EXT1
EXT1 Module
Expansion modules (with board
EXT1-T):
- 2x VF impulse inputs NAMUR,
- 6x digital inputs
- 2x analog inputs
- 2x connection of digital
transducer
S0-EXT1/HF
EXT1/HF Module
Expansion module:
- 2x VF impulse inputs NAMUR,
S1N-COM1 *)
COM1 Module
Communication module
RS232/RS485
SLOT 1,
SLOT 2
S1N-2AI *)
AI Module
Analog inputs modules
4-20 mA (2 inputs)
S1N-2AO *)
AO Module
Analog outputs modules
4-20 mA (2 inputs)
S4N-PWR3
PWR3 Module
External power supply module
of EVC and internal modem
SLOT 4
S4N-PWR4/24V
PWR4 Module
External power supply module
of EVC and internal modem
S4N-PWR4/12V
PWR4 Module
External power supply module
of EVC and internal modem
M2G
Modem 2G
Internal modem 2G
(according
to the
design of
the device)
M4G, LTE-Cat1E
Modem LTE-Cat 1 Mod E
Internal modem LTE, cat. 1-E
M4G, LTE-Cat1U
Modem LTE-Cat 1 Mod U
Internal modem LTE, cat. 1-US
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...