Fig. 33 EDT 96 and EDT 101 transducers connection
The EDT 96 pressure transmitter and the EDT 101 temperature transmitter are supplied by the
manufacturer calibrated in whole measurement range. The calibration and correction data are
stored in the transducer´s internal memory when the transmitter is calibrated and the resulting
measured data already included with the corrections is passed to the instrument control unit.
Nevertheless, the device is equipped with the option of
one-point or two-point adjustment
of
the transducer using the supplied SW [42], [43]. This option is protected by the metrology switch
provided by the metrology mark. In the case of a corrector without MID metrological verification or
an electronic data logger, the adjustment is accessible to the user. A description of the corrector
settings via user SW is given in [38].
For more information on EDT 101 and EDT 96 transducers, see [39] and [40].
5.6.6 Connecting External Power Supply
A cable with a minimum cross section of 0.75 mm
2
is required for the external power supply from
the PS-E (PS-E/A) intrinsically safe power supply.
To connect the external power supply to internal modem from the PS-M (PS-M/A) intrinsically
safe power supply, cable with the conductor cross section of at least 1 mm
2
is required. The table
below shows the maximum length of this cable. The PG9 cable gland is designed for the cable. If
both the corrector and the internal modem are powered from external power supply, the only one
4-core cable can be used for the power supply.
Connection
Cable
Cable
gland
Recommended type of cable Max.
lenght
Cable Ø
External power supply of
the corrector (separate)
2-wire
shielded
PG9
(PG7)
Unitronic LiYCY 2 x 0.75
Lappkabel
30 m
6.0 mm
External power supply of
the modem (separate)
2-wire
shielded
PG9 Unitronic LiYCY 2 x 1.5
Lappkabel, or
20 m
7.1 mm
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...