4
Explosion Safety Parameters
40
Ci = 0.46uF
Li = 0
8/
ELCORplus version only
EXT1, EXT1/HF board (KP 100 130) – Digital Iputs: DI1, DI2 (NAMUR):
(SLOT 0 TERMINALS:
DI1-,DI1+,DI2-,DI2+)
8/
Uo = 10,0V
Io = 11mA
Po = 27mW
IIB
IIA
Co
20uF
100uF
Lo
1mH
1mH
Ui = 5,5 V
Ii = 1 mA
Pi = 1 mW
Ci = 0, Li = 0
8/
ELCORplus version only
EXT1 board (KP 100 130) – Digital Iputs: DI3 to DI8:
(terminals EXT-1T: GND, DI3,DI4, DI5,
DI6, DI7, DI8)
8/
Uo = 6.5V
Io = 2mA
Po = 3mW
IIB
IIA
Co
20
F
100
F
Lo
10mH
100mH
Ui = 5,5 V
Ii = 1 mA
Pi = 1 mW
Ci = 0, Li = 0
8/
ELCORplus version only
EXT1 board (KP 100 130) - AIN analogue inputs:
(terminals EXT1-T: GND, AI1, GND, AI2)
8/
Ui = 28V
Ii = 93mA
Pi = 0.66W
Ci = 40nF
Li = 0
8/
ELCORplus version only
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...