5
Installation and Commissioning
52
Fig. 10 Mounting dual channel ELCORplus on a mounting plate
5.4.2 Mounting the Device on a Pipe
Clamps
10
(see Fig. 11) with spacings corresponding to the pipe diameters are reeved
through the openings in the mounting plate
4
and inserted over the pipe. Fasteners
11
are
fixed onto the free ends of the clamps by means of nuts M6
14
and washers
12
and
13
to secure the mounting plate in the desired position on the pipe. The mounting plate can be
used for fixing to a pipe of diameter:
DN80 - DN200 for horizontal piping, or
DN80 - DN150 for vertical piping.
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...