Appendix
2: ELCORplus version for Zone 2
191
Module EXT1 (KP 100 130) – analog inputs AIN:
(terminals EXT1-T: GND, AI1, GND, AI)
Ui = 28 V
Ii = 93 mA
Pi = 0,66 W
Ci = 40 nF
Li = 0
Module EXT1 (KP 100 130) - Internal Bus IB1:
(terminals EXT1-T: GND, U+, D+, D-)
8/
Same parameters as Internal Bus IB0 and IB1
8/
only for ELCORplus
3.2 Terminals with protections „nA“
Digital outputs DOUT:
(terminals U0+, GND0, DO1, DO2, DO3, DO4)
U = 15 V
RS485 interface - KP 100 110:
(terminals SLOT1,2 TERMINALS: D+, D-, GND, U+)
U = 5 ÷ 15 V
RS232 interface - KP 100 110:
(terminals SLOT1,2 TERMINALS: GND, CTS, RXD, TXD)
U = ± 15 V
Analog inputs AIN - KP 100 112:
(terminals SLOT1,2 TERMINALS: GND, AI1, GND, AI2)
I = 0 ÷ 25 mA
Analog outputs AO - KP 100 113:
(terminals SLOT1,2 TERMINALS: AO1+, AO1-, AO2+, AO2-)
U = 5 ÷ 28 V
Power voltage 230 VAC
(module PWR3, TERMINALS: N,L)
Un = 100 ÷ 240 VAC, 50/60 Hz
Power voltage 24 VDC
(
module PWR4/24, TERMINALS: +U, -U)
Un = 20 ÷ 32 VDC
Power voltage 12 VDC
(
module PWR4/12, TERMINALS: +U, -U)
Un = 10 ÷ 16 VDC
Degree of cover protection: IP66
Ambient temperature: -25 °C ≤ Ta ≤ +60 °C
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...