1
Introduction
12
protection of metrological parts by an official MID seal
protection of selected non-metrological parts by the manufacturer's identification seal or by
the user's identification seal
Tampering device detection
detection of the opening of the device with the possibility of sending an alarm (
detection of removing metrological covers with the possibility of sending an alarm
detection of an attempt to disturb the function of a mechanical indexer by an external
magnetic field
Device configuration and data protection (11.6)
metrological switch - secured by the official MID seal, blocks the execution of operations
that directly modify the metrological characteristics of the instrument (eg measuring
accuracy, calibration of transducers, exchange of transducers, setting of converted volume
counters, etc.)
service switch - is used to block parameter settings that do not directly affect the device's
metrological properties
password security - optionally, you can use 50 passwords in 5 groups with different
hierarchy of authority to modify the device settings
encryption - protection of transmitted data by encryption (symmetric AES encryption with
128-bit encryption key length) This option is optional and can be used for data
transmission by ELGAS protocol, ver.2 or CTR protocol. (par. 10.4)
All changes to device parameter settings, along with the worker's identification mark, are stored in
an indelible setting archive.
1.3 Versions of the Device
The gas volume corrector is manufactured and supplied in two types designated as ELCOR and
ELCOR
plus
, which differ in features, internal extension options and dimensions. The ELCOR and
ELCOR
plus
correctors are certified for commercial measurement according to 2014/32/EU.
The ELCOR
plus
corrector is also manufactured with an integrated mechanical indexer under the
name ELCOR
plus Indexer.
In terms of design and most of the technical parameters, DATCOM and DATCOM
plus
are
identical with ELCOR and ELCOR
plus;
however, from the measurement point of view, they are
not approved gauges and are primarily intended as electronic data loggers. They cannot be used
for commercial measurement purposes.
1.3.1 ELCOR, DATCOM
The ELCOR (DATCOM) device is a single-channel battery-powered device with an optional
internal communication modem and with an interface for connecting a gas meter equipped with
an encoder. The device does not have an external power supply option.
Depending on the equipment, it may exist in the following versions:
a) Basic version:
- Single channel battery-powered corrector
- Six-key keypad
- Graphic or segment display
- 1 x digital pressure transducer EDT 96
- 1 x digital temperature transducer EDT 101
- 1 x pulse input for connecting a gas meter with LF pulse output
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...