6
Operating the Device
97
6.7 Device Configuration Menu
In this menu, the device parameters can be set directly from the device keypad.
i
Setting device parameters from the keypad can be protected:
By the service switch (the switch must be set to ON)
By a password (for more details, refer to Section 11.6.2)
If the service switch is set to OFF, the message "Parameters cannot be set"
appears in the display.
The following parameters can be set:
Service parameters
- Station Identification
- Gas hour
Communication
- General parameters
- IR head
- Communication protocol
- Internal modem
- Serial COM1
- Serial COM2
... (the baud rate and communication protocol are
set separately for each communication)
Gas composition
- N2 concentration
- CO2 concentration
- Combustion heat
- Relative density
... (the parameters depend on the calculation
method selected)
Date/Time
HH:MM/DD:MM:YYYY
Volume parameters
(Totalizers 1,2)
- kp1, kp2 Gas meter constant [imp/m3]
- Vm1, Vm2 Primary volume
(-Vb1, Vb2 Volume at base conditions)
- Vs1, Vs2 Substitute primary volume
(- Vbs1, Vbs2 Substitute volume at base
conditions)
(- E Energy)
(- Es Substitute Energy)
- Serial numbers of the gas meters
- Qmax1, Qmax2 Max. gas flow rate
Archive reset
Data archive
Daily archive
Monthly archive
Billing archive
Binary archive
Limit archive
(Settings Archive)
(Status Archive)
(Gas composition archive)
Work mode
normal (standard)
Saving parameters
Entering the changed parameters in the device
Summary of Contents for DATCOM
Page 38: ...3 Technical Parameters 36 ...
Page 50: ...5 Installation and Commissioning 48 Fig 7 Examples of data plates ...
Page 83: ...5 Installation and Commissioning 81 Fig 37 Communication via RS232 RS485 using B RS module ...
Page 115: ...7 Technical Description of the Device 113 Fig 57 Functional diagram of ELCOR ...
Page 116: ...7 Technical Description of the Device 114 Fig 58 Functional diagram of ELCORplus ...
Page 122: ...7 Technical Description of the Device 120 Fig 61 Modem replacement ...
Page 159: ...10 Communication with the Device 157 packet ...
Page 174: ...12 Accessories 172 Fig 78 ELCORplus example of use of external modules ...
Page 213: ...Appendix 3 Compass Data Export 211 Preview of generated document ...
Page 215: ...Appendix 3 Compass Data Export 213 3 Export to XLS 4 Export to TXT DOC ...
Page 216: ...Appendix 3 Compass Data Export 214 ...
Page 217: ...Appendix 3 Compass Data Export 215 5 Export of graph ...