M-Bus Display / Datalogger 

 

 

MR005FA / MR005DL 
MR006FA / MR006DL 

 

 

M-Bus Remote Displays and Datalogger 

for 3 or 20 Slaves 

 

User Manual 

Summary of Contents for MR005DL

Page 1: ...M Bus Display Datalogger MR005FA MR005DL MR006FA MR006DL M Bus Remote Displays and Datalogger for 3 or 20 Slaves User Manual...

Page 2: ...tion and startup 4 3 Description of the Level Converter 7 4 Description of the M Bus Display 9 5 Keyboard operation 10 6 Remote control with commands 15 7 Additional functions of the Datalogger 15 8 P...

Page 3: ...level converter for 20 meters MR006DL Display datalogger and level converter for 20 meters Accessories NT003 Plug in power supply 12 VDC 500mA NT013 Power supply 24 VDC regulated 15W for rail mountin...

Page 4: ...Bus devices are wired polarity independent in parallel to the same line The characters mark only the different bus lines Earth for symmetry of M Bus Power V Power supply positive terminal for DC 10 28...

Page 5: ...9 are not connected Simultaneous use of interfaces In case of a local readout using the keyboard of the remote display or during an automatic readout the RS232 interfaces do not have access to the M...

Page 6: ...readout of this meter No reply from meter Check baudrate and address of this meter Check the bus extension The bus voltage must be 24V at any slave Temporarily remove other bus segment Status Error MR...

Page 7: ...ters The members of the MR005 family are able to supply up to 3 the members of the MR006 family up to 20 slaves unit loads with power Technical Data Supply Voltage 10 28VDC 5W 13 28VAC 9W Environment...

Page 8: ...ance between a slave and the master is inverse dependent on the number of slaves in this segment and on the cable diameter The maximum allowed resistance of the cable can be estimated The calculation...

Page 9: ...s under the terminal lid compartment and also on the LCD If there are problems with interpretation of the M Bus data the display shows Status Error The list of errors is shown on the LCD after simulta...

Page 10: ...backlighted display for comfortable local access to all functions The buttons give a very precise mechanical feedback and each input is acknowledged by an acoustic signal beep Execution of menu entrie...

Page 11: ...ns activated temporary or permanent error bits in the Status byte an E will be shown The first character follows one digit for the device 0 main device Filtering data To make the readout of data easy...

Page 12: ...o these functions Shows the list of slaves Allows editing of Primary address ID and baudrate The meter data of all devices are read and displayed on the LCD based on the list of slaves After selecting...

Page 13: ...hows the ID of location description Change of passcode B global access Selects passcode mode Standard requests passcode on startup Access by ID Adr requests ID address for single read Manually starts...

Page 14: ...ers You should check the entries of the list of slaves from the menu List of slaves Show edit list Editing the list of slaves The entries in the list of slaves can also be edited by the user using the...

Page 15: ...rt this format Therefore we offer a special solution called M Bus modem for use with any level converter and also with MR00xDL FA in level converter mode In spite of this the command mode makes use of...

Page 16: ...inimum 15 x 65536 1820 540 readouts The practice shows that usually there are often installations with less meters and shorter M Bus telegrams Download of stored data The contents of the data memory c...

Page 17: ...rminal and connect the PC to the modem Choose 9600 baud 8 data bits no parity and one stopbit Then input the following commands and activate each with the Enter key Command Function AT for baudrate de...

Page 18: ...User Manual MR005FA DL MR006FA DL 04 2018 VERSION 1 4 18 MR005FA DL MR006FA DL 10 CE Declaration...

Page 19: ...User Manual MR005FA DL MR006FA DL 04 2018 VERSION 1 4 19 MR005FA DL MR006FA DL Notes...

Page 20: ......

Reviews: