background image

User

’ 

s Guide

Shop online at

omega.com

R

HH520

T

4 Channel  ype J, K, T, E

 

Data Logger Thermometer

NORWALK, CT

e-mail: [email protected]

For latest product manuals:

www.omegamanual.info

Summary of Contents for HH520

Page 1: ...User sGuide Shop online at omega com R HH520 T 4 Channel ype J K T E Data Logger Thermometer NORWALK CT e mail info omega com For latest product manuals www omegamanual info...

Page 2: ...pecifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Cana...

Page 3: ...TUP Button 6 7 Operating Instructions 6 7 1 Setup Options 6 7 2 Menu Item 6 7 3 Menu Description 8 7 3 1 Select thermocouple type 8 7 3 2 Setting interval time for data storing 8 7 3 3 Set offset to c...

Page 4: ...herwise the protection provided by the meter may be impaired ENVIRONMENT CONDITIONS Altitude up to 2000 meters Relatively humidity 90 max Operation ambient temperature 0 C to 50 C MAINTENANCE CLEARING...

Page 5: ...4 F below 100 C 148 F 0 4 of reading 0 7 C 0 4 of reading 1 4 F Temperature coefficient 0 01 of reading 0 05 C per C 18 C or 28 C Sample rate 2 time per second Battery type UM 4 or AAA 1 5V battery x...

Page 6: ...led indicator Recording data logger indicator Memory full indicator Memory group indicator Recall Memory group reading indicator Thermocouple type Temperature reading Temperature channel Temperature s...

Page 7: ...C Button 2 Display Screen 9 RECALL Saved Reading Button 3 Power ON OFF Button 10 SETUP Button 4 Back Light Button 11 MEM Button Set 100 Memory 5 MAX MIN AVG Button 12 USB Interface 6 DATA HOLD Button...

Page 8: ...g recording period most of the buttons are disabled such as the All settings must be made before starting the data logger function Note When the memory is full 16000 recorders symbol will blink on the...

Page 9: ...tton again the and symbol blinks together the readings shows real time data To exit MAX MIN AVG mode Press and hold button for 2 seconds to exit MAX MIN AVG mode 6 8 Selecting Temperature Units Press...

Page 10: ...LOGGER THERMOMETER 7 2 Fig 2 Set interval time for data logging 3 Fig 3 Set offset to compensate for probe errors 4 Fig 4 Set alarm point 5 Fig 5 Set T1 T2 subtraction mode 6 Fig 6 Set auto power off...

Page 11: ...offset to compensate for probe errors The user can adjust the readings of thermometer to compensate for the errors against a specific thermocouple 1 Press the or button to select thermocouple channel...

Page 12: ...will display at the bottom of LCD see Fig 16 7 3 6 Set auto power off time Press the or button to select auto power off option 10 30 minutes 1 2 4 8 hours or off see Fig 17 or Fig 18 7 3 7 Set system...

Page 13: ...before SUrE 0 The LCD will show CLr 0 and start erasing group 00 to 99 records 7 6 Connecting to a computer The meter can be connected to PC through a micro USB cable to download recorded data or per...

Page 14: ...rt with the cable 2 Start HH520 program 3 If the connection is successful the panel will display the same value as the 4 Channel Thermometer If fail to connect the meter with PC it will display No Con...

Page 15: ...much fewer disk space to save the data than the other two file formats but it can only be used in HH520 Text file can be opened by HH520 and any other word processor program like word notepad etc EXCE...

Page 16: ...from tool bar 7 In reference to Data Logger see DataLogger 9 7 Main Menu File Oepn Retrieve files from the disk Save Save the active window when the caption bar is highlighted data to the disk Print...

Page 17: ...PC select DataLogger from main menu or click Datalogger icon from tool bar to load recorded data from the meter and there will be a progress indicator to show the loading status If error occurs just...

Page 18: ...sor When selected the mouse cursor will become a cross sign when moving to the graph click on the graph to mark a cross sign on the graph This is available only when Split option is unchecked And all...

Page 19: ...TALOGGER THERMOMETER 16 Seperate the four channel Combine the four channel Graph Customization Change the Y axis extention Note When the Split is unchecked graph will use T1 as the Y axis display rang...

Page 20: ...er Press the left mouse button and drag the cursor to select the new extents then release the mouse button 3 When I setup the real time sampling with a fast rate eg 1 sec Some of the sampling data mig...

Page 21: ...DATALOGGER THERMOMETER 18 NOTE...

Page 22: ...DATALOGGER THERMOMETER 19 NOTE...

Page 23: ...y OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limite...

Page 24: ...Air Velocity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps...

Reviews: