30
Utilities functions
Use
“UTILITY key” to
select
different
functions.
The button-LED
is
turned
ON.
User interface analisys
Manual
Defrost
The user
can activate
the defrost
process
manually. The temperature display shows
the
message
“
dEFr
” which
will
hold
over for
all
the time. If
press two
time the utility
button
when
the icon defrost
is
ON the defrost
will
start,(with
door
closed
by
air inside cell,
with
door
open with
room air ) and it
stopped
when
the temperature of evaporator
reach
7°C.
Manual
Defrost
At the end of the process
the logic
control return to
stand by