TB_VTX2009-06.doc- Page 1 of 2
Identification:
Technical Bulletin:
Date:
Issuer:
Factory:
E 22 / E 23
VTX2009-06
06 July 2009
Giusti Lorenzo - Customer Support
VTX - Refrigeration - Pordenone
Subject:
Alarm E13
(REAL TIME CLOCK FAILURE)
Model :
Blast chiller and freezer CW and LW
Reason :
The correct sequence can be used to reset the alarm
E13
Action in
Factory:
/
Action in
Field:
When alarm E13 appears, first all set the
year-
month- Day – hours- minutes
.
ERROR CODE E13:
REAL TIME CLOCK FAILURE
When an Alarm appears due to Real time clock failure the red Alarm
Service led is flashing and the buzzer is active. The display on the user
interface shows the ERROR codes E13 (see Picture 1).
This type of error causes the following possible events:
1.
The electronic control looses data and time setting values.
Check all of User’s parameters and if is necessary regulate them
This is the exact sequence to set:
year -month- Day – hours-
minutes.
Other sequences can cause possible un-reset of the alarm
E13
Picture 1: ERROR CODE E13
Picture 2: Internal battery
Summary of Contents for BLAST CHILLER LW
Page 1: ...BLAST CHILLER LW 595R18700 ...
Page 3: ...Electronic control Cruise version CRUISE version ...
Page 53: ...Blast Chiller or Freezer First point installation Code check Safety device Description ...
Page 92: ...Remote cooling unit information What you must know to respect a correct installation ...
Page 102: ... T1 T2 AP AP AT AT Electrical connection Find the terminals inside the electrical box ...