SAFETY DEVICE
Voltage adaptor Fuse
It’s installed in all BC&BCF and cut off power supply to the
door frame heater
in case of short circuit.
It means that the hot cable inside of the door frame will be off.
Normally the door frame heater is ON if the difference of
temperature between the cell and ambient is higher then
parameter value
dFt
(i.e. -30°C)
.It’s positioned inside the
electric box, on Voltage adaptor from 230/42V
Technical data:
Type:
Fuse from 0.63 Amp
Dimension:
5x20
“
T
”= delayed-action
“
F
”= fast
59